Cabling Specifications; Maximum Cabling Distances - Panasonic ICX Technical Manual

Hide thumbs Also See for ICX:
Table of Contents

Advertisement

Section 200 - General Description

Cabling Specifications

Maximum Cabling Distances

Loop Type Resistance
Key Telephone, EM/24
DSS/72
SLT
Doorphone (loop between the
ICX and Doorphone Adapters)
Doorphone (loop between the
Doorphone Adapter and the
Doorphone)
NOTE: If a TAPI box or Voice Response Telephone Adapter is installed with the telephone, the measured resistance must be
less than 20 Ohms and the maximum cabling distance reduced in half compared to a standard key telephone.
ICX-40-200
Resistance
Cable Gauge (AWG)
40 Ohms
20 Ohms
100 Ohms
10 Ohms
10 Ohms
ICX (International) issued December 1999
Chapter 6 - Specifications
Maximum Cabling Length in Feet
(distance from the ICX)
22
24
26
22
24
26
22
24
26
22
24
26
22
24
26
1239
779
490
619
330
245
3097
1948
1225
309
194
122
1239
779
490
87