Figure 5
4. Slide pulley cover (A, Figure 6) over pulley
spindles and secure with two screws (A
5. Lift up on motor base (A
pulley grooves. Release motor base to allow
belt to tension. Tighten nut (A
to secure belt tension.
Figure 6

5.7 Vertical cutting plate

NOTE: The following steps apply only when using
band saw in vertical mode.
1. Disconnect band saw from power source.
2. Raise bow to vertical position and use support
(R, Figure 7) to secure in position. (If support
will not slide into recess, vertical stop may need
adjustment. See sect. 7.12)
3. Loosen bolt (S, Figure 7) just enough to slide
stand (E) behind bolt. Tighten bolt just enough
to hold stand in position.
4. Remove two flat head screws (T) and bearing
guard (U). [Note: Bearing guard (U) must be
reinstalled when returning to horizontal mode.]
5. Guide blade through slot in vertical cutting plate
(D, Figure 7) and fasten cutting plate with the
two screws.
6. Fasten stand (E) to underside of table using
screw and hex nut (HP6/7). Bracket may need
to be bent slightly to accommodate plate.
7. Tighten bolt (S).
).
1
) and place belt around
2
) on motor base
3

6.0 Electrical connections

The HVBS-56M Band Saw is rated at 115/230V
power, and is pre-wired for 115 volt. The band saw
comes with a plug designed for use on a circuit with
a grounded outlet that looks like the one pictured in
A, Figure 8.
Before connecting to power source, be sure switch
is in off position.
It is recommended that the band saw be connected
to a dedicated 15 amp circuit with circuit breaker or
fuse. If connected to a circuit protected by fuses, use
time delay fuse marked "D". Local codes take
precedence over recommendations.

6.1 GROUNDING INSTRUCTIONS

This machine must be grounded. In the event of a
malfunction or breakdown, grounding provides a
path of least resistance for electric current to reduce
the risk of electric shock. This tool is equipped with
an electric cord having an equipment-grounding
conductor and a grounding plug. The plug must be
plugged into a matching outlet that is properly
installed and grounded in accordance with all local
codes and ordinances.
Do not modify the plug provided - if it will not fit the
outlet, have the proper outlet installed by a qualified
electrician.
Improper connection of the equipment-grounding
conductor can result in a risk of electric shock. The
conductor with insulation having an outer surface
that is green with or without yellow stripes is the
equipment-grounding
replacement of the electric cord or plug is
necessary, do not connect the equipment-grounding
conductor to a live terminal.
electrician or service personnel if the grounding
instructions are not completely understood, or if
in doubt as to whether the tool is properly
8
Figure 7
conductor.
If
repair
Check
with
a
qualified
or

Advertisement