Hvps (High Voltage Power Supply) Section; Hvps Specification; Chg-Bias (Charge Bias)/Grid/ Unit - Panasonic DP-MB310EU Service Manual

Table of Contents

Advertisement

6.15. HVPS (High Voltage Power Supply) Section

6.15.1. HVPS Specification

Charge (CHG)
Output Characteristics
Constant current
Nominal Output Voltage 4.35KV
Nominal Output Current 200±15µA
(19.4MΩ)
Load Range
18.1MΩ~20.6MΩ
Constant
Current
4.1~4.6KV
Range
As for the developing voltage, the DC voltage and AC voltage are overlapped and output from an output terminal.
There is one terminal for transcription output and + and - are switched to be output.

6.15.2. CHG-BIAS (Charge BIAS)/GRID/ UNIT

When IC300 turns on the transistor Q506, CHG REM becomes "L", and Charge BIAS (200µA) is output from CHG OUTPUT.
GRID BIAS is generated by the current flowing in the GRID circuit via charge wire and GRID.
KX-MB2230EU/ KX-MB2270EU/ KX-MB2515EU/ KX-MB2545EU/ KX-MB2575EU/ DP-MB310EU
Grid
Developing DC
(DEV DC)
Constant voltage
Constant voltage
475±10V
230V±15V
(50~300V)
PWM20%
300MΩ/220pF
200µA
0.73µA
-----
100MΩ~2000MΩ
-----
-----
95
Developing AC
Transfer (TRA) -
(DEV AC)
Constant voltage
Constant current
(Variable)
330V±15Vp-p
100MΩ
34KHz
(-1.48KV)
-14.8µA±1µA
-----
(0µA~25µA)
PWM 35%
-----
33.8MΩ~284MΩ
-----
-0.5KV ~ -4.2KV
Transfer (TRA) +
Constant voltage
785V±100V
1000MΩ
(0.8µA)
10MΩ~1000MΩ
-----

Advertisement