Allied Air A96US2V Installation Instructions Manual page 73

Warm air gas furnace upflow/horizontal left air discharge direct vent & non-direct vent
Table of Contents

Advertisement

Program Unit Capacity / Size Mode
1)
Refer to figures 53 and 54 for field wiring when using the Comfort Sync thermostat. Refer to tables 12A,
12B, 12C, and 12D for field wiring for all non-communicating applications.
2)
If the furnace is being matched with a non-communicating heat pump, refer to the instructions packaged
with the dual fuel thermostat.
3)
See figure 53
4)
Refer to tables 12A, 12B, 12C, and 12D
Power-Up – Number displayed represented by integrated control unit size code(furnace model and capacity). If
three horizontal bars are displayed followed by a continuous E203, furnace control does not recognize unit size
code. Configure per the following:
Verify that the furnace is in idle mode; signified by a flashing dot in the corner of the 7 segment LED display.
Press and hold the button next to the display, until a solid "P" appears. Release the button. Note: replacement
control boards may need to be manually configured to validate the furnace unit size code.
The solid "P" starts blinking. Release the button.
Push and hold the button until unit size codes are displayed. See chart below. When the correct unit size code is
displayed, release the button. The selected code will flash for 10 seconds. During that period, press and hold the
button for 5 seconds. The integrated control will store the code in memory and automatically exit and reset. (If
the 10 seconds expire or the button is held for less than 5 seconds, the control will automatically exit and go into
idle mode without storing the unit size code. If this happens, repeat steps to configure the unit size.)
Verify that the selected unit size code is correct and stored in non-volatile memory. To do this, cycle 24v power
to the control. When the board powers up, the 7 segment LED will display the unit size code. If three horizontal
bars are displayed, this indicates that the board does not recognize a unit size code; programming of the board
will need to be repeated.
0 =
1 =
2 =
3 =
4 =
5 =
6 =
7 =
507404-04
Unit Size Chart
A96US2V045B12S-01
A96US2V070B12S-01
A96US2V090C12S-01
A96US2V090C16S-01
A96US2V090C20S-01
A96US2V110C16S-01
A96US2V110C20S-01
A96US2V135D20S-01
8 =
A96DS2V045B12S-01
9 =
A96DS2V070B16S-01
11 =
A96DS2V090C20S-01
U =
A96DS2V110C20S-01
Issue 1621
Page 73 of 80