Allied Air A96US2V Installation Instructions Manual page 50

Warm air gas furnace upflow/horizontal left air discharge direct vent & non-direct vent
Table of Contents

Advertisement

EL296 Field Wiring Applications With Conventional Thermostat (Continued)
DIP Switch Settings and On-Board Links (figure 60)
DIP Switch 1
Thermostat
Thermostat
Dual Fuel
Single Stage
Heat Pump
ComfortSense
7000 L7724U
thermostat w/
dual fuel capa­
bilities
Capable of 2
stage gas heat
control
Dual Fuel
Two Stage
Heat Pump
ComfortSense
7000 L7724U
thermostat w/
dual fuel capa­
bilities
Capable of 2
stage gas heat
control
* Connect W1 to W1 ONLY if using defrost tempering kit 67M41
NOTE - Do NOT make a wire connection between the room thermostat L terminal and the L terminal of the EL296
integrated control.
Page 50 of 80
Page 50 of 80
Field Wiring Applications with Conventional Thermostat (continued)
On Board Links Must Be Cut To Select
Heating
Stages
OFF
CUT ON-BOARD LINK
W951
HEAT
PUMP
OFF
CUT ON-BOARD LINK
W915
2 STAGE
COMPR
CUT ON-BOARD LINK
W951
HEAT
PUMP
TABLE 11
System Options
Table 13C
Page 45
Issue 1406
Issue 1621
Wiring Connections
FURNACE
L7724U
TERM. STRIP
T'STAT
H
67M41*
L
Y2
D
B
Y2
T
T
L7724U
FURNACE
T'STAT
TERM. STRIP
H
67M41*
L
Y2
D
B
T
outdoor
sensor
T
HEAT PUMP
L
Y
outdoor
sensor
HEAT PUMP
L
Y2
out blue
507404-01
507404-04