Allied Air A96US2V Installation Instructions Manual page 54

Warm air gas furnace upflow/horizontal left air discharge direct vent & non-direct vent
Table of Contents

Advertisement

A96US2V090C20S BLOWER PERFORMANCE (less filter)
0 through 0.8 in. w.c. (Heating) and 0 through 1.0 in. w.c. (Cooling) External Static Pressure Range
Heating Speed Dip
1
Switch Setting
+24%
+18%
+12%
+6%
Fauctory Default
-6%
-12%
-18%
Cooling Speed DIP
1
Switch Settings
+
Factory
-
Cooling and Heating speed are based on a combination of DIP switch setting on the furnace control. Refer to installation instructon for specific DIP
1
Switch settings
Factory default setting
2
NOTES: The effect of static pressure is included in air volumes shown.
First stage Cool (two stage air conditioning units only) is approximately 70% of the same second stage COOL speed position
Continous Fan Only speed approximately 50% of the selected second stage cooling speed - minimum 500cfm.
A96US2V110C16S BLOWER PERFORMANCE (less filter)
0 through 0.8 in. w.c. (Heating) and 0 through 1.0 in. w.c. (Cooling) External Static Pressure Range
Heating Speed Dip
1
Switch Setting
+24%
+18%
+12%
+6%
Fauctory Default
-6%
-12%
-18%
Cooling Speed DIP
1
Switch Settings
+
Factory
-
Cooling and Heating speed are based on a combination of DIP switch setting on the furnace control. Refer to installation instructon for specific DIP
1
Switch settings
Factory default setting
2
NOTES: The effect of static pressure is included in air volumes shown.
First stage Cool (two stage air conditioning units only) is approximately 70% of the same second stage COOL speed position
Continous Fan Only speed approximately 50% of the selected second stage cooling speed - minimum 500cfm.
Page 54 of 80
First Stage heating Speed - cfm
1425
1355
1290
1220
1150
1080
1010
945
First Stage Cooling Speed -cfm
Low
Medium-Low
Medium-High
935
1073
850
975
765
880
First Stage heating Speed - cfm
1520
1445
1370
1300
1225
1150
1080
1005
First Stage Cooling Speed -cfm
Low
Medium-Low
Medium-High
770
935
700
850
630
765
HEATING
COOLING
High
Low
2
1240
1405
1320
1125
1275
1200
1015
1150
1080
HEATING
COOLING
High
Low
2
1075
1235
1100
975
1125
1000
880
1015
900
Issue 1621
Second Stage Heating Speed-cfm
1920
1830
1735
1645
1550
1460
1365
1270
Second Stage Cooling Speed-cfm
Medium-Low Medium-High
1540
1760
1400
1600
1260
1440
Second Stage Heating Speed-cfm
1610
1535
1455
1380
1300
1225
1145
1065
Second Stage Cooling Speed-cfm
Medium-Low Medium-High
1320
1540
1200
1400
1080
1260
High
2
2010
1825
1640
High
2
1760
1600
1440
507404-04