EL296 Field Wiring Applications With Conventional Thermostat (Continued)
DIP Switch 1
Thermostat
Thermostat
Dual Fuel
Single Stage
Heat Pump
ComfortSense
7000 L7742U
thermostat w/
dual fuel capa­
bilities
Capable of 2
stage gas heat
control w/dehu­
midification
control
Dual Fuel
Two Stage
Heat Pump
ComfortSense
7000 L7742U
thermostat w/
dual fuel capa­
bilities
Capable of 2
stage gas heat
control w/dehu­
midification
* Connect W1 to W1 ONLY if using defrost tempering kit 67M41
NOTE - Do NOT make a wire connection between the room thermostat L terminal and the L terminal of the EL296
integrated control.
507404-01
507404-04
Field Wiring Applications with Conventional Thermostat (continued)
DIP Switch Settings and On-Board Links (figure 60)
On Board Links Must Be Cut To Select
Heating
Stages
OFF
CUT ON-BOARD LINK
W951
HEAT
PUMP
CUT ON-BOARD LINK
W914
DEHUM
OR
HARMONY
CUT ON-BOARD LINK
OFF
2 STAGE
COMPR
CUT ON-BOARD LINK
W951
HEAT
PUMP
CUT ON-BOARD LINK
W914
DEHUM
HARMONY
TABLE 11
System Options
W915
OR
Table 13D
Page 46
Issue 1406
Issue 1621
Wiring Connections
FURNACE
L7742U
TERM. STRIP
T'STAT
H
67M41*
L
Y2
D
B
Y2
T
T
FURNACE
L7742U
TERM. STRIP
T'STAT
H
67M41*
L
Y2
D
B
Y2
T
T
HEAT PUMP
L
Y
outdoor
sensor
HEAT PUMP
L
Y2
out blue
outdoor
sensor
Page 51 of 80
Page 51 of 80