Page 1
USE AND MAINTENANCE MANUAL Codice Code 257759003 GE 7500 HBSL - AVR Codigo Kodezahl GE 7500 HBSLE - AVR Edizione Edition 05.2014 Edición Ausgabe M A D E I T A L Y...
Page 3
DESCRIPTION OF THE MACHINE GE 7500 HBSL-AVR GE 7500 HBSLE-AVR REV.0 - 05/14 The generating set is a unit which transforms the mechanical energy, generated by endothermic engine, into electric energy, through an alternator. The assembling is made on a steel structure, on which are provided elastic support which must damp the vibrations and also eliminate sounds which would produce noise.
Page 4
· Competent support in the solution of problems; ofthe International Certification Network IQNet, · Information and training in the correct applicatio- awarded the official approval to MOSA after an- nand use of the products to assure the security examination of its operations at the head office ofthe operator and protect the environment;...
Page 5
INDEX GE 7000 HBSL/ HBSLE - AVR GE 7500 HBSL/ HBSLE - AVR REV.0 - 05/14 DESCRIPTION OF THE MACHINE M 01 QUALITY SYSTEM M 1.01 COPYRIGHT M 1.1 NOTES M 1.4 CE MARKING M 1.4.1 DECLARATION OF CONFORMITY M 1.5 TECHNICAL DATA SAFETY PRECAUTIONS M 2.1...
Page 6
(see page M1.1). All rights are reserved to said Company. It is a property logo of MOSA division of B.C.S. S.p.A. All other possible logos contained in the documen- tation are registered by the respective owners.
Notes REV.1-03/14 INFORMATION INFORMATION OF GENERAL TYPE In the envelope given together with the machine and/or Dear Customer, set you will find: the manual for Use Maintenance and We wish to thank you for having bought a high quality set. Spare Parts, the manual for use of the engine and the tools (if included in the equipment), the guarantee (in the Our sections for Technical Service and Spare Parts will...
Page 8
CE MARKING REV.7-02/14 Any of our product is labelled with CE marking attesting its conformity to appliable directives and also the fulfillment of safety requirements of the product itself; the list of these directives is part of the declaration of conformity included in any machine standard equipment. Here below the adopted symbol: CE marking is clearly readable and unerasable and it can be either part of the data-plate.
Konformitätserklärung Dichiarazione conformità Declaration of conformity Declaración de conformidad 1.4.1 Déclaration de conformité Declaração de conformidade REV.2-10/13 BCS S.p.A. Stabilimento di Cusago, 20090 (Mi) - Italia V.le Europa 59 Sede legale: Tel.: +39 02 903521 Via Marradi 1 Fax: +39 02 90390466 20123 Milano - Italia DICHIARAZIONE DI CONFORMITA' Déclaration de Conformité...
Page 10
TECHNICAL DATA GE 7500 HBSL-AVR GE 7500 HBSLE-AVR REV.0 - 05/14 Technical data GE 7500 HBSL-AVR GE 7500 HBSLE-AVR GENERATOR Stand-by three-phase power 8 kVA (6.4 kW) / 400V / 11.5 A PRP three-phase power 7 kVA (5.8 kW) / 400V / 10.1 A PRP single-phase power 3 kVA / 230V / 13 A Frequency...
Page 11
WARNINGS REV.1-02/14 The installation and general warnings regarding operations are aimed achieving correct use of the machine and/or apparatus in the place where it is used as a genset and/or motor welder. - Advice to the User about the safety: + NB: The information contained in the manual can be changed without notice.
SYMBOLS AND SAFETY PRECAUTIONS REV.2-06/10 SYMBOLS PROHIBITIONS No harm for persons Use only with safety clothing - STOP - Read absolutely and be duly attentive It is compulsory to use the personal protection means given in equip- ment. Use only with safety clothing - Read and pay due attention It is compulsory to use the personal protection means given in equipment.
INSTALLATION AND ADVICE REV.1-06/07 Check that the air gets changed completely and the hot INSTALLATION AND ADVICE BEFORE USE air sent out does not come back inside the set so as to cause a dangerous increase of the temperature. GASOLINE ENGINES Use in open space, air swept or vent exhaust gases, which contain the deathly carbone oxyde, far from the work area.
Installazione Luftzirkulation Installation Instalación GE 7000 HBSL/ HBSLE - AVR Installation GE 7500 HBSL/ HBSLE - AVR REV.0 - 05/14...
Page 15
Dimensioni Abmessungen Dimensions Dimensiones GE 7000 HBSL/ HBSLE - AVR 2.7.1 Dimensions GE 7500 HBSL/ HBSLE - AVR REV.0 - 05/14 STANDARD STD + CTM7/1 STD + CTM7/2...
Page 16
UNPACKING REV.1-02/04 NOTE + Be sure that the lifting devices are: correctly mounted, adequate for the weight of the machine with it’s pack- aging, and conforms to local rules and regulations. When receiving the goods make sure that the product has not suffered damage during the transport, that there has not been rough handling or taking away of parts contained inside the packing or in the set.
Page 17
TRANSPORT AND DISPLACEMENTS COVERED UNITS REV.2-09/11 NOTE Transportation must always take place with the engine off, electrical cables and starting battery disconnected and fuel tank empty. Be sure that the lifting devices are: correctly mounted, adequate for the weight of the machine with it’s packaging, and conform to local rules and regulations.
Page 18
ASSEMBLY CTM 7/1 - CTM 7/2 6.23 REV.0-05/14 Note: Lift the machine and assemble the parts as shown in the drawing CTM 7/1 CTM 7/2 ATTENTION The CTM accessory cannot be removed from the machine and used separately (actioned manually or following vehicles) for the transport of loads or anyway for used different from the machine mo- vements.
SET-UP FOR OPERATION GE 7500 HBSL-AVR GE 7500 HBSLE-AVR REV.0 - 05/14 FUEL BATTERY WITHOUT MAINTENANCE Check the level of fuel in the tank and, if necessary, add The included battery must be activated. unleaded gasoline.For further information regarding the To activate it (fill the included acid) please follow the in- fuel which has to be used, see instructions in the engine structions shown on the manual attached to the battery.
STARTING AND STOPPING THE ENGINE GE 7000 HBSL/ HBSLE - AVR GE 7500 HBSL/ HBSLE - AVR REV.0 - 05/14 Electric start to check before every starting 4) Turn the start-up key (Q1) to the ON position. 5) Turn the start-up key (Q1) to the START NOTE position, once the engine is started up leave the key, it will reposition itself in...
Page 21
Comandi Bedienelemente Controls Mandos GE 7500 HBSL-AVR Commandes GE 7500 HBSLE-AVR REV.0 - 05/14 SCHUKO VERS. * HBSL vers. - ** HBSLE vers. Pos. Descrizione Description Description Descripción Morsetto di terra PE Earth terminal Prise de mise à terre Toma de puesta a tierra Presa di corrente in c.a.
Page 22
Using the generator REV.3-11/11 are the same. WARNING + In the absence of a load, the values for voltage and frequency can be greater than their nominal values. See It is absolutely forbidden to connect the unit sections on VOLTAGE and FREQUENCY. to the public mains and/or another electrical power source .
Page 23
Using the generator REV.1-09/05 The frequency, and therefore the number of motor SINGLE-PHASE LOADS revolutions, is maintained constant by the motor’s speed Power to monophase utilities by means of three-phase regulation system. generators requires some operating limitations. Generally, this regulator is of a mechanical type and - In single-phase operation, the declared voltage presents a droop from no-load to nominal load which tolerance can no longer be maintained by the regulator...
Using the generator REV.1-09/05 DIFFERENTIAL SWITCH USAGE WITH EAS AUTOMATIC START-UP PANEL The differential switch or differential relay guarantee The electricity-generating group in combination with the protection against indirect contacts due to malfunction EAS automatic start-up panel forms a unit for distributing currents towards the ground.
Page 25
MAINTENANCE REV.1-01/13 WARNING ● Have qualified personnel do maintenance and troubleshooting work. ● Stop the engine before doing any work inside the machine. If for any reason the machine must be operated while working inside, pay at- tention moving parts, hot parts (exhaust manifold and muffler, etc.) electrical parts which may be unprotected when the machine is open.
TROUBLE-SHOOTING GE 7000 HBSL/ HBSLE - AVR 40.2 GE 7500 HBSL/ HBSLE - AVR REV.0 - 05/14 WARNING ● Have qualified personnel do maintenance and troubleshooting work. ● Stop the engine before doing any work inside the machine. If for any reason the machine must be operated while working inside, pay attention moving parts, hot parts (exhaust manifold and muffler, etc.) electrical parts which may be unprotected when the machine is open.
STORAGE REV.0-06/07 In case the machine should not be used for more than 30 days, make sure that the room in which it is stored presents a suitable shelter from heat sources, weather changes or anything which can cause rust, corrosion or damages to the machine.
Page 28
CUST OFF REV.0-06/07 Have qualified personnel disassemble the In case of necessity for first aid and fire prevention, machine and dispose of the parts, including the see page M2.5. oil, fuel, etc., in a correct manner when it is to be taken out of service.
Page 29
ELECTRICAL SYSTEM LEGENDE REV.10-05/13 A : Alternator E3 : Open circuit voltage switch I6 : Start Local/Remote selector N9 : UP/DOWN button mast B : Wire connection unit F3 : Stop push-button L6 : Choke button O9 : Hydraulic unit solenoid valve C : Capacitor G3 : Ignition coil M6 : Switch CC/CV P9 : Hydraulic unit engine D : G.F.I. H3 : Spark plug N6 : Connector – wire feeder Q9 : Ignitor E : Welding PCB transformer I3 : Range switch O6 : 420V/110V 3-phase transformer...
Page 30
Stromlaufplan GE 4500 HBS / HBS - AVR Schema elettrico Electric diagram GE 4500 SX 61.1 Schemas electriques GE 7000-7500 HBSL - AVR REV.1-07/11...
Page 31
Stromlaufplan Schema elettrico Electric diagram Esquema eléctrico GE 7000-7500 HBSLE - AVR 61.2 Schemas electriques REV.0-05/14...
Page 32
Stromlaufplan Schema elettrico Electric diagram Esquema eléctrico GE 7500 HBSL/ HBSLE - AVR 61.3 Schemas electriques REV.0-05/14...
Page 34
WWW.MOSA.IT MOSA div. della BCS S.p.A. Stabilimento di Viale Europa, 59 20090 Cusago (MI) Italia Tel. + 39 - 0290352.1 Fax + 39 - 0290390466...
Need help?
Do you have a question about the GE 7500 HBSLE - AVR and is the answer not in the manual?
Questions and answers