Samsung MH080FXEA4B Installation Manual page 7

Hide thumbs Also See for MH080FXEA4B:
Table of Contents

Advertisement

C
I
OMPLETING THE
NSTALLATION
Deciding on where to install the Air Conditioner (Continue)
MH060FXEA3B

Indoor unit
026/035/052
CAUTION:
3 m as minimum pipe length: It will reduce
noise and vibration.
This value must be increased at 7.5 meters in
case it is connected just one indoor unit.
300 mm
minimum
600 mm
minimum
Piping length and the height
Dimension
Composition
System can work with one indoor unit connected, but it is recommended that the TOTAL number
of indoor unit suggested by manufacturer are connected to obtain the maximum performance.
8
E-
FJM_IM_DB98-31792_E_6.10.10.indd 8
Power supply
Outdoor unit
Ø, V, Hz
MH060FXEA3B
1,220-240, 50
600 mm
A
minimum
300 mm
minimum
1 Room max
3 Room total max
length
length
20m
45 m
A,B,C
A+B+C
Make at least one round:
It will reduce noise and vibration
The appearance of the unit may be different from the diagram depending on the model.
Piping outside diameter
Unit
026/035
052
B
Main power switch
Max height between
Max height between
indoor unit & outdoor unit
indoor units
15m
7.5 m
(H)
(h)
Outside diameter
Liquid
Gas
3/8"
1/4"
1/2"
(h) (H)
C
2010-6-10 9:53:24

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mh070fxea4bMh060fxea3bMh050fxea2 series

Table of Contents