2. Tuner
Measuring instruments: Signal generator, sweep generator, oscilloscope, frequency counter.
Function switch: Radio
Adjustment
1. AM IF
Couple in a sweep signal of 465kHz to L506 (ferrite aerial)
via a loop aerial.
Oscilloscope to testpoint TP5 / TP4 (GND).
Band switch: MW
2. MW Oscillator
Var. capacitor to limit stop: MW f
Couple in a standard signal to L506 (ferrite aerial) via a
loop aerial, (f
that the signal is just visible).
Oscilloscope to testpoint TP5 / TP4 (GND).
Band switch: MW
3. MW Aerial
MW 600kHz, MW 1400kHz
bandpass
Couple in a standard signal to L506 (ferrite aerial) via a
loop aerial, (f
that the signal is just visible).
Oscilloscope to testpoint TP5 / TP4 (GND).
Band switch: MW
4. LW Oscillator
Var. capacitor to limit stop: f
Couple in a standard signal to L505 (ferrite aerial) via a
loop aerial, (f
that the signal is just visible).
Oscilloscope to testpoint TP5 / TP4 (GND).
Band switch: LW
5. LW Aerial
LW 153kHz, LW 261kHz
bandpass
Couple in a standard signal to L505 (ferrite aerial) via a
loop aerial, (f
that the signal is just visible).
Oscilloscope to testpoint TP5 / TP4 (GND).
Band switch: LW
6. FM Oscillator
Var. capacitor to limit stop: FM f
Couple in a standard signal via a 10nF capacitor to
testpoint TP1 / TP2 (GND) (f
as low as possible so that the signal is just visible).
Oscilloscope to testpoint TP5 / TP4 (GND).
Band switch: FM
7. FM Aerial band-
FM 88MHz, FM 106MHz
pass
Couple in a standard signal via a 10nF capacitor to
testpoint TP1 / TP2 (GND) (f
as low as possible so that the signal is just visible).
Oscilloscope to testpoint TP5 / TP4 (GND).
Band switch: FM
Preparations
515kHz, f
u
o
= 1kHz, m = 30%, U
as low as possible so
a
mod
= 1kHz, m = 30%, U
as low as possible so
a
mod
292kHz
o
= 1kHz, m = 30%, U
as low as possible so
a
mod
= 1kHz, m = 30%, U
as low as possible so
mod
a
87.35MHz, f
u
= 1kHz, ∆f = 22.5kHz, U
mod
= 1kHz, ∆f = 22.5kHz, U
mod
Adjust to maximum with T501.
1635kHz
At f
(515kHz) adjust to maximum with L504.
u
At f
(1635kHz) adjust to maximum with VCT501(D).
o
Repeat this adjustment alternately.
At 600kHz adjust to maximum with L506 (MW aerial coil,
move).
At 1400kHz adjust to maximum with VCT501(C).
Repeat this adjustment alternately.
At f
(292kHz) adjust to maximum with TC501.
o
At 153kHz adjust to maximum with L505 (LW aerial coil,
move).
At 261kHz adjust to maximum with TC502.
Repeat this adjustment alternately.
108.25MHz
At f
(87.35MHz) adjust to maximum with L503.
o
u
At f
(108.25MHz) adjust to maximum with VCT501(C).
o
Repeat this adjustment alternately.
a
At 88MHz adjust to maximum with L502 (bend).
At 106MHz adjust to maximum with VCT501(D).
Repeat this adjustment alternately.
a
2 - 4