Connecting To The Device - Siemens RUGGEDCOM RS900GP Installation Manual

Hide thumbs Also See for RUGGEDCOM RS900GP:
Table of Contents

Advertisement

Chapter 2
Installing the Device
Figure 4: Failsafe Alarm Relay Wiring
1. Normally Open
2. Common
Section 2.4

Connecting to the Device

The following describes the various methods for accessing the ROS console and Web interfaces on the device.
For more detailed instructions, refer to the ROS User Guide for the RS900GP.
Serial Console and Management Ports
Connect a PC or terminal directly to the serial console port to access the boot-time control and ROS interfaces.
The serial console port provides access to ROS's console interface.
IMPORTANT!
The serial console port is intended to be used only as temporary connection during initial configuration
or troubleshooting.
The serial console port implements RS232 DCE (Data Communication Equipment) on a DB9 connector. The
following is the pin-out for the port:
Figure 5: Serial DB9 Console Port
8
3. Normally Closed
5
1
9
6
1
2
3
Pin
Name
1
2
3
4
5
GND
6
7
8
9
RUGGEDCOM RS900GP
Installation Guide
Description
Reserved (Do Not Connect)
TX
Transmit Data
RX
Receive Data
Reserved (Do Not Connect)
Common Ground
Reserved (Do Not Connect)
Reserved (Do Not Connect)
Reserved (Do Not Connect)
Reserved (Do Not Connect)
Connecting to the Device