A96UHMV110C20S BLOWER PERFORMANCE (less filter)
RIGHT SIDE RETURN AIR WITH OPTIONAL RETURN AIR BASE
HEATING BLOWER PERFORMANCE
Heating Adjust CFM Selections
Increase (+15%) Heat CFM
Increase (+7.5%) Heat CFM
Default Heat CFM
Decrease (-7.5%)'Heat CFM
Decrease (-15%) Heat CFM
COOLING BLOWER PERFORMANCE
Cooling Adjust CFM
Selections
increase (+10%) Cool CFM
Default Cool CFM
Decrease (-10%) Cool CFM
A96UHMV135D20S BLOWER PERFORMANCE (less filter)
BOTTOM RETURN AIR
HEATING BLOWER PERFORMANCE
Heating Adjust CFM
Selections
Increase (+15%) Heat CFM
Increase (+7,5%) Heat CFM
Default Heat CFM
Decrease (-7.5%) Heat CFM
Decrease (-15% ) Heat CFM
COOLING BLOWER PERFORMANCE
Cooling Adjust CFM
Selections
increase (+10%) Cool CFM
Default Cool CFM
Decrease (-10%) Cool CFM
The effect of static pressure is included in air volumes shown.
The following control configurations are available. See Installation Instructions for details and DIP switch settings.
Heat Modes Available (Heating Blower Performance Table):
Single stage thermostat:
- 40%, 70%. 100% input (three-stage) with time delays in-between
Two-stage thermostat:
- Variable Rate Capacity Mode - furnace automatically adjusts firing rate based on first- and second-stage cycle times
- W1 demand at 70% input, W2 demand at 100% input. No delay between stages
Cool Mode Available (Cooling Blower Performance table):
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position,
Continuous Fan speeds are approximately 38% of the same second-stage COOL speed position minimum 300 cfm.
Page 58 of 74
BLOWER DATA
Heating input Range and Blower Volume - CFM
40%
50%
893
1068
814
986
736
903
680
833
623
762
Blower Speed Selections
First Stage Cool Speed- cfm
Low
Medium
Medium
Low
High
918
1022
1205
839
955
1084
760
865
984
Heating input Range and Blower Volume - CFM
40%
50%
1033
1200
957
1113
881
1026
817
956
753
886
Blower Speed Selections
First Stage Cool Speed- cfm
Low
Medium
Medium
Low
High
935
1074
1260
834
983
1116
732
867
1023
Issue 1622
60%
70%
80%
1243
1419
1594
1157
1329
1500
1071
1238
1406
986
1139
1293
901
1040
1179
Second Stage Cool Speed-cfm
High
Low
Medium
(Default)
Low
1371
1268
1487
1235
1158
1369
1109
1030
1224
60%
70%
80%
1367
1534
1701
1269
1426
1582
1172
1317
1463
1095
1235
1374
1019
1152
1284
Second Stage Cool Speed-cfm
High
Low
Medium
(Default)
Low
1450
1353
1567
1306
1202
1448
1145
1080
1290
90%
100%
1770
1945
1672
1843
1573
1741
1446
1599
1318
1457
Medium
High
High
(Default)
1726
1913
1568
1764
1393
1575
90%
100%
1868
2035
1738
1895
1608
1754
1513
1652
1417
1550
Medium
High
High
(Default)
1751
1994
1616
1828
1472
1668