A96UHMV090C20S BLOWER PERFORMANCE (less filter)
RIGHT SIDE RETURN AIR
HEATING BLOWER PERFORMANCE
Heating Adjust CFM Selections
Increase (+15%) Heat CFM
Increase (+7.5%) Heat CFM
Default Heat CFM
Decrease (-7.5%)'Heat CFM
Decrease (-15%) Heat CFM
COOLING BLOWER PERFORMANCE
Cooling Adjust CFM
Selections
increase (+10%) Cool CFM
Default Cool CFM
Decrease (-10%) Cool CFM
A96UHMV090C20S BLOWER PERFORMANCE (less fil-
ter)
AIR BASE
Heating Adjust CFM Selections
Increase (+15%) Heat CFM
Increase (+7,5%) Heat CFM
Default Heat CFM
Decrease (-7.5%) Heat CFM
Decrease (-15% ) Heat CFM
COOLING BLOWER PERFORMANCE
Cooling Adjust CFM
Selections
increase (+10%) Cool CFM
Default Cool CFM
Decrease (-10%) Cool CFM
The effect of static pressure is included in air volumes shown.
The following control configurations are available. See Installation Instructions for details and DIP switch settings.
Heat Modes Available (Heating Blower Performance Table):
Single stage thermostat:
- 40%, 70%. 100% input (three-stage) with time delays in-between
Two-stage thermostat:
- Variable Rate Capacity Mode - furnace automatically adjusts firing rate based on first- and second-stage cycle times
- W1 demand at 70% input, W2 demand at 100% input. No delay between stages
Cool Mode Available (Cooling Blower Performance table):
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position,
Continuous Fan speeds are approximately 38% of the same second-stage COOL speed position minimum 300 cfm.
507028-03
BLOWER DATA
Heating input Range and Blower Volume - CFM
40%
50%
684
835
623
769
562
702
502
633
441
564
First Stage Cool Speed- cfm
Low
Medium
Medium
Low
High
911
1043
1227
805
960
1087
700
840
991
Heating input Range and Blower Volume - CFM
40%
50%
686
837
626
771
566
705
502
633
437
560
First Stage Cool Speed- cfm
Low
Medium
Medium
Low
High
913
1037
1230
827
953
1088
741
855
995
Issue 1622
60%
70%
80%
986
1136
1287
914
1059
1205
842
953
1123
765
896
1028
687
810
932
Blower Speed Selections
Second Stage Cool Speed-cfm
High
Low
Medium
(Default)
Low
1434
1335
1559
1296
1173
1433
1115
1049
1283
RIGHT SIDE RETURN AIR WITH OPTIONAL RETURN
HEATING BLOWER PERFORMANCE
60%
70%
80%
987
1138
1288
916
1060
1205
844
983
1121
764
895
1026
683
806
930
Blower Speed Selections
Second Stage Cool Speed-cfm
High
Low
Medium
(Default)
Low
1415
1329
1560
1278
1177
1414
1117
1044
1261
90%
100%
1437
1588
1350
1496
1263
1403
1159
1291
1055
1178
Medium
High
High
(Default)
1719
1986
1568
1811
1451
1603
90%
100%
1439
1589
1349
1494
1260
1399
1157
1288
1053
1176
Medium
High
High
(Default)
1740
1982
1586
1807
1432
1619
Page 53 of 74