A96UHMV110C20S BLOWER PERFORMANCE (less filter)
BOTTOM RETURN AIR
HEATING BLOWER PERFORMANCE
Heating Adjust CFM Selections
Increase (+15%) Heat CFM
Increase (+7.5%) Heat CFM
Default Heat CFM
Decrease (-7.5%)'Heat CFM
Decrease (-15%) Heat CFM
COOLING BLOWER PERFORMANCE
Cooling Adjust CFM
Selections
increase (+10%) Cool CFM
Default Cool CFM
Decrease (-10%) Cool CFM
A96UHMV110C20S BLOWER PERFORMANCE (less filter)
RIGHT SIDE RETURN AIR
HEATING BLOWER PERFORMANCE
Heating Adjust CFM
Selections
Increase (+15%) Heat CFM
Increase (+7,5%) Heat CFM
Default Heat CFM
Decrease (-7.5%) Heat CFM
Decrease (-15% ) Heat CFM
COOLING BLOWER PERFORMANCE
Cooling Adjust CFM
Selections
increase (+10%) Cool CFM
Default Cool CFM
Decrease (-10%) Cool CFM
The effect of static pressure is included in air volumes shown.
The following control configurations are available. See Installation Instructions for details and DIP switch settings.
Heat Modes Available (Heating Blower Performance Table):
Single stage thermostat:
- 40%, 70%. 100% input (three-stage) with time delays in-between
Two-stage thermostat:
- Variable Rate Capacity Mode - furnace automatically adjusts firing rate based on first- and second-stage cycle times
- W1 demand at 70% input, W2 demand at 100% input. No delay between stages
Cool Mode Available (Cooling Blower Performance table):
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position,
Continuous Fan speeds are approximately 38% of the same second-stage COOL speed position minimum 300 cfm.
507028-03
BLOWER DATA
Heating input Range and Blower Volume - CFM
40%
50%
861
1049
825
1000
789
951
731
883
673
816
Blower Speed Selections
First Stage Cool Speed- cfm
Low
Medium
Medium
Low
High
937
1064
1247
864
972
1146
790
888
1025
Heating input Range and Blower Volume - CFM
40%
50%
733
825
708
794
683
763
632
707
580
650
Blower Speed Selections
First Stage Cool Speed- cfm
Low
Medium
Medium
Low
High
918
1053
1198
820
964
1095
722
852
987
Issue 1622
60%
70%
80%
1237
1424
1612
1174
1349
1524
1112
1274
1436
1035
1187
1339
958
1101
1243
Second Stage Cool Speed-cfm
High
Low
Medium
(Default)
Low
1407
1312
1560
1282
1219
1405
1167
1075
1272
60%
70%
80%
1009
1194
1378
967
1139
1312
924
1085
1245
857
1007
1157
790
929
1069
Second Stage Cool Speed-cfm
High
Low
Medium
(Default)
Low
1366
1270
1519
1231
1170
1363
1116
1059
1218
90%
100%
1800
1988
1699
1874
1597
1759
1491
1644
1386
1528
Medium
High
High
(Default)
1744
1955
1569
1796
1428
1634
90%
100%
1562
1747
1484
1657
1406
1566
1307
1457
1209
1348
Medium
High
High
(Default)
1712
1899
1555
1774
1401
1581