Allied Air A97USMV Installation Instructions Manual page 49

Warm air gas furnace
Table of Contents

Advertisement

A96UHMV070B12S BLOWER PERFORMANCE (less filter)
RIGHT SIDE RETURN AIR WITH OPTIONAL RETURN AIR BASE
HEATING BLOWER PERFORMANCE
Heating Adjust CFM Selections
Increase (+15%) Heat CMS
Increase (-7.5%) Heat CFM
Default Heat CFM
Decrease (-7.5% ) Heat CFM
Decrease (-15% ) Heat CFM
COOLING BLOWER PERFORMANCE
Cooling Adjust CFM
Selections
Increase (+10%) Cool CFM
Default Cool CFM
Decrease (-10%) Cool CFM
A96UHMV090C12S BLOWER PERFORMANCE (less filter)
TOM RETURN AIR HEATING
BLOWER PERPORMANCE
Heating Adjust CFM Selections
Increase (15%) Heat CFM
Increase (+7.5%) Heat CFM
Default Heat CFM
Decrease(-7.5% ) Heat CFM
Decrease (-15% ) Heat CFM
COOLING BLOWER PERFORMANCE
Cooling Adjust CFM
Selections
Increase (+10%) Cool CFM
Default Cool CFM
Decrease (-10%) Cool CFM
The effect of static pressure is included in air volumes shown.
The following control configurations are available. See Installation Instructions for details and DIP switch settings.
Heat Modes Available (Heating Blower Performance Table):
Single stage thermostat:
- 40%, 70%. 100% input (three-stage) with time delays in-between
Two-stage thermostat:
- Variable Rate Capacity Mode - furnace automatically adjusts firing rate based on first- and second-stage cycle times
- W1 demand at 70% input, W2 demand at 100% input. No delay between stages
Cool Mode Available (Cooling Blower Performance table):
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position,
Continuous Fan speeds are approximately 38% of the same second-stage COOL speed position minimum 300 cfm.
507028-03
BLOWER DATA
40%
50%
519
614
480
570
441
526
408
486
375
446
First Stage Cool Speed- cfm
Low
Medium
Medium
Low
High
585
715
815
520
655
755
490
595
670
40%
50%
734
827
697
792
660
737
616
687
572
637
First Stage Cool Speed- cfm
Low
Medium
Medium
Low
High
625
710
830
565
670
760
520
610
685
Issue 1622
Heating Input Range and Blower Volume - CFM
60%
70%
709
805
660
751
611
696
564
643
517
589
Blower Speed Selections
Second Stage Cool Speed-cfm
High
Low
(Default)
950
855
840
790
745
720
Heating Input Range and Blower Volume - CFM
60%
70%
821
1014
867
953
814
891
757
828
701
788
Blower Speed Selections
Second Stage Cool Speed-cfm
High
Low
(Default)
950
875
860
800
785
720
80%
90%
1
900
996
1091
841
931
1021
781
866
951
721
799
877
660
732
803
Medium
Medium
High
Low
High
(Default)
1045
1205
1350
945
1090
1255
845
985
1130
BOT-
80%
90%
100%
1108
1201
1295
1038
1123
1209
968
1045
1122
899
970
1041
830
895
959
Medium
Medium
High
Low
High
(Default)
1040
1210
1380
945
1100
1240
840
970
1115
Page 49 of 74