A96UHMV090C16S BLOWER PERFORMANCE (less filter)
BOTTOM RETURN AIR
HEATING BLOWER PERFORMANCE
Heating Adjust CFM Selections
Increase (+15%) Heat CFM
Increase (+7.5%) Heat CFM
Default Heat CFM
Decrease (-7.5% ) Heat CFM
Decrease (-15% ) Heat CFM
COOLING BLOWER PERFORMANCE
Cooling Adjust CFM
Selections
Increase (+10%) Cool CFM
Default Cool CFM
Decrease (-10%) Cool CFM
A96UHMV090C16S BLOWER PERFORMANCE (less filter)
RIGHT SIDE RETURN AIR
HEATING BLOWER PERFORMANCE
Heating Adjust CFM Selections
Increase (15%) Heat CFM
Increase (+7.5%) Heat CFM
Default Heat CFM
Decrease(-7.5% ) Heat CFM
Decrease (-15% ) Heat CFM
COOLING BLOWER PERFORMANCE
Cooling Adjust CFM
Selections
Increase (+10%) Cool CFM
Default Cool CFM
Decrease (-10%) Cool CFM
The effect of static pressure is included in air volumes shown.
The following control configurations are available. See Installation Instructions for details and DIP switch settings.
Heat Modes Available (Heating Blower Performance Table):
Single stage thermostat:
- 40%, 70%. 100% input (three-stage) with time delays in-between
Two-stage thermostat:
- Variable Rate Capacity Mode - furnace automatically adjusts firing rate based on first- and second-stage cycle times
- W1 demand at 70% input, W2 demand at 100% input. No delay between stages
Cool Mode Available (Cooling Blower Performance table):
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position,
Continuous Fan speeds are approximately 38% of the same second-stage COOL speed position minimum 300 cfm.
507028-03
BLOWER DATA
40%
50%
835
968
776
902
716
836
652
767
589
699
First Stage Cool Speed-cfm
Low
Medium
Medium
Low
High
840
1005
1155
780
915
1045
690
835
955
40%
50%
812
943
759
882
706
821
644
755
582
690
First Stage Cool Speed- cfm
Low
Medium
Medium
Low
High
820
1005
1135
755
880
1025
680
815
925
Issue 1622
Heating Input Range and Blower Volume- CFM
60%
70%
1101
1234
1028
1155
955
1075
882
997
809
919
Blower Speed Selections
Second Stage Cool Speed-cfm
High
Low
(Default)
1315
1165
1190
1075
1070
935
Heating Input Range and Blower Volume - CFM
60%
70%
1073
1204
1005
1127
936
1051
867
978
797
905
Blower Speed Selections
Second Stage Cool Speed-cfm
High
Low
(Default)
1290
1140
1150
1040
1065
910
80%
90%
1
1367
1500
1633
1281
1407
1534
1195
1314
1434
1112
1227
1342
1029
1139
1249
Medium
Medium
High
Low
High
(Default)
1375
1580
1770
1265
1440
1645
1145
1320
1465
80%
90%
100%
1334
1465
1595
1250
1372
1495
1165
1280
1395
1089
1200
1312
1013
1120
1228
Medium
Medium
High
Low
High
(Default)
1340
1525
1725
1235
1395
1565
1120
1275
1400