Electrical System; Normal Control Board Operation - Follett HMD1000N Operation And Service Manual

Hide thumbs Also See for HMD1000N:
Table of Contents

Advertisement

Electrical system

Normal control board operation

The PC board indicator lights provide all the information necessary to determine the machine's status. Green
indicator lights generally represent "go" or normal operation; Yellow indicators represent normal off conditions;
Red indicators generally represent alarm conditions, some of which will lock the machine off.
A green light labeled POWER indicates power to the machine. A fl ashing green light labeled CPU is normal and
indicates that the Central Processing Unit "heart beat" is working. All other normal operation status indicators are
covered as follows:
Ice machine disposition
Legend:
ON
OFF
ON or OFF
1.
Ice machine is making ice.
2. Ice machine is not making ice.
3. Ice machine is not making ice.
Operating conditions
FLASHING
1.
Normal running.
2. Normal time delay. When the bin fi lls with ice, the LOW BIN
light goes out and the refrigeration and auger drive systems
immediately shut down. The TIME DELAY light comes on,
initiating the time delay period. When the time delay expires,
the machine will restart provided that the LOW BIN light is on.
3. Normal purge indicator. After a selected period of ice
making time has elapsed (1 or 2 hours), the ice machine will
automatically self-fl ush. The refrigeration system will shut
down but the gear motor will continue to run. After the fl ush is
complete the machine will refi ll and start without a time delay.
14

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hmf1000rHcfHmdHcd

Table of Contents