Download Print this page

Ruckus Wireless R600 Quick Setup Manual page 3

Hide thumbs Also See for R600:

Advertisement

Mounting on a Recessed Drop-Ceiling T-Bar
Note: This mounting bracket can also be used on a flush
drop-ceiling T-bar, so the four rubber feet on the bottom
of the AP minimize ceiling tile displacement.
The enclosed T-bar bracket supports mounting to recessed
drop ceiling T-bars.
Mounting an AP using the External Bracket
Removing an External Bracket from a T-Bar
Removing an External Bracket from an AP
Mounting an AP using the External Bracket
1
Insert the unit removal pin (A in
Figure
the side of the R600 (B in
Figure
4) to release the locking
mechanism.
Figure 4. Attaching the external bracket to the AP
A
B
2
Position the studs on the bottom of the T-bar bracket (C
in
Figure
4) in the mounting holes on the R600 enclosure,
and then slide the T-bar bracket until the studs are in the
narrow parts of the R600 mounting keyholes (arrow).
3
Remove the unit removal pin (A in
Figure
the locking mechanism and secure the T-bar bracket to
the R600.
4
Make sure that the locking tab (D in
first position on the T-bar bracket (C in
5
Gently push the ceiling tiles up and out of the way.
6
Position the T-bar bracket so its two clasps grip one edge
of the T-bar (A in
Figure
5). Make sure that both clasps
are gripping the T-bar.
Figure 5. Attaching the external bracket to the T-bar
A
B
Copyright © 2014 Ruckus Wireless, Inc.
Published September 2014, Part Number 800-70633-001 Rev B
7
Hold the R600 in place and gently push the locking tab
(B in
Figure
bar.
CAUTION:
bar!
Removing an External Bracket from a T-Bar
1
Move the ceiling tiles out of the way.
2
Gently lift up the locking tab (A in
your fingers under the tab.
While lifting up on the locking tab, rotate the R600-
3
and-T-bar bracket assembly (B in
4) into the hole on
and-T-bar bracket assembly comes away from the T-
bar.
Figure 6. Removing the external bracket from the T-bar
C
D
Removing an External Bracket from an AP
Insert the unit removal pin (A in
1
on the side of the R600.
Gently lift up the retainer tab (B in
2
Gently push the T-bar bracket (C in
3
4) to engage
detaches from the R600.
Figure 7. Removing the external bracket from an AP
Figure
4) is in the
Figure
4).
5) until its clasp grips the other edge of the T-
Make sure that all three clasps are gripping the T-
Figure 6
) by sliding
Figure 6
). The R600-
A
B
) into the hole
Figure 7
).
Figure 7
) until it
Figure 7
A
C
B
Mounting on a Flush Drop-Ceiling T-Bar
Mounting an AP using the Integrated Bracket
Removing an AP Integrated Bracket from a T-Bar
Mounting an AP using the Integrated Bracket
Orient the AP so that the T-bar is positioned between
1
the T-bar clips as shown in
Figure 8
until the third T-bar clip catches the T-bar and the
latch locks the T-bar in place (
Figure 9
Figure 8. Attaching the integrated bracket to the T-bar
Figure 9. Locking the integrated bracket to the T-bar
2
Insert the Torx security screw into the hole near the
latch to lock the AP in place.
Removing an AP Integrated Bracket from a T-Bar
To remove the AP from a T-bar, first remove the
1
security screw, then depress the latch while rotating
the AP so that the T-bar clips disengage the T-bar.
Mounting on a Truss or Pole
Feed the customer-supplied cable ties through the
1
two slots on the back of the R600.
2
Fasten the R600 to the truss or pole using the cable
ties.
, then rotate the AP
).
Page 3 of 4

Advertisement

loading