Model
Item
Programming method/Control method
Control unit
Number of
controllable I/O points
Front switch input
Program memory
Built-in memory
Program capacity
Basic
Number of instruction
High-level
Operation speed
I/O update and Base time
Internal relay (R)
Special internal relay (R)
Timer/Counter (T/C)
Data register (DT)
Special data register (DT)
Index registers (IX. IY)
Differential points
Master control relay points (MCR)
Number of labels (JP and LOOP)
Number of step ladders
Number of subroutines
Number of interrupt programs
Self-diagnostic function
Clock/calendar function
Note 2)
Battery life
Pulse catch input
Interrupt input
COM. port
Note 3)
Periodical interrupt
Constant scan
Password
High-speed counter function
* The combinations 1-phase × 2 ch.
and 2-phase × 1 ch. are also possible
for the high-speed counter.
Output points
Pulse
output function
Output frequency
Output points
PWM output
function
Output frequency
Timer
Counter
Non-hold type
Counter
Hold type
Non-hold type
Internal relay
Hold type
Non-hold type
Data register
Hold type
Note 1)
The proportion of timer points to counter points can be changed using a system register.
Note 2)
Precision of calendar timer:
- At 0°C/32°F, less than 200 seconds of error per month
- At 25°C/77°F, less than 70 seconds of error per month
- At 55°C/131°F, less than 240 seconds of error per month
Note 3)
When using the COM. port for communication, retransmission is recommended.
The RS232C driver IC for the COM. port conforms completely to EIA/TIA-232E and
CCITT V. 28 standards
Note 4)
The max. counting speed (10 kHz) is the counting speed with a rated input voltage of 24 V
DC and an ambient temperature of 25°C. The counting speed (frequency) will decrease
depending on the voltage and temperature.
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
AFPE224300
AFPE224302
Standard type
Standard type
(RS232C)
(RS485)
Relay symbol/Cyclic operation
14 points [Input: 8, Output: 6 (Tr. NPN: 5/Ry: 1)]
8 points
Built-in EEP-ROM
2,720 steps
83
117
0.9 µs/step (Basic instruction)
Typical 2 ms
1,008 points (R0 to R62F)
64 points (R9000 to R903F)
144 points (Initial setting: 100 timer points, T0 to T99/44 counter points, C100 to C143
Timer range (1 ms, 10 ms, 100 ms, 1 s): selected by instruction
1,660 words (DT0 to DT1659)
112 words (DT9000 to DT9111)
2 points
Unlimited number of points
32 points
64 labels
128 stages
16 subroutines
7 programs (external: 6, internal 1)
Watchdog timer, program syntax check, etc.
Available (year, month, day, hour, minute,
second and day of week). However, this can
Not available
only be used when a battery has been
installed.
220 days or more (actual usage value:
approx. 870 days (25°C). (Periodic
Not available
replacement interval: 1 year). (Value applies
when no power is supplied at all.)
6 points in total (X0 and X1: 50 µs, X2 to X5: 100 µs)
RS232C
RS485
0.5 ms to 30 s
Available
Available
Counter mode: Addition/subtraction (1-phase)
Note 4)
- Max. speed: 10 kHz (total of 4 ch.)
- Input contact: X0: count input (ch. 0), X1: count input (ch. 1), X2: reset input
X3: count input (ch. 2), X4: count input (ch. 3), X5: reset input
- Min. input pulse width: X0 and X1: 50 µs (10 kHz)
X3 and X4: 100 µs (5kHz)
Counter mode: 2-phase/individual/direction decision (2-phase)
- Max. speed: 2 kHz (total of 2 ch.)
- Input contact: X0: count input (ch. 0), X1: count input (ch. 0), X2: reset input
X3: count input (ch. 2), X4: count input (ch. 2), X5: reset input
- Min. input pulse width: X0 and X1: 50 µs (10 kHz)
X3 and X4: 100 µs (5 kHz)
2 independent points (Y0 and Y1) (No interpolation function)
Note 6)
40 Hz to 10 kHz (Y0/Y1: 1-point)
40 Hz to 5 kHz (Y0/Y1: 2-point)
2 points (Y0 and Y1)
Frequency: 0. 15 Hz to 1 kHz
Duty: 0.1 % to 99.9 %
Non-hold type: (all points)
From set value to C139
4 points (elapsed values) C140 to C143
976 points (R0 to R60F)
61 words (WR0 to WR60)
32 points (R610 to R62F)
2 words (WR61 to WR62)
1,652 words (DT0 to DT1651)
8 words (DT1652 to DT1659)
Note 5)
If the unit is equipped with both reset inputs X0 and X1, X2 serves as the reset input for X1.
If X3 and X4 are used, X5 serves as the reset input for X4.
Note 6)
When the positioning control instruction "F168" is performed, the maximum output
frequency is 9.5 kHz.
Note 7)
The program, system registers and the hold type area (internal relay, data register, and
timer/counter) are backed up by the built-in EEP-ROM.
When a battery is replaced with a new one in the FP-e unit with a calendar timer function,
settings can be changed without installing a battery. The data cannot be stored even when
the settings are changed using the system register.
Note 8)
F180 (SCR) and F181 (DSP) instructions are supported from Control FPWIN GR Ver. 2.2.
and FPWIN Pro V 4.1.
AFPE224305
AFPE214325
Calendar timer type
Thermocouple input
Thermocouple input
(RS232C)
type (RS232C)
12 points [Input: 6, Output: 6 (Tr. NPN: 5/Ry: 1)]
Note 1)
Not available
Not available
RS232C
RS232C
- Input points: 4 ch. (Max.)
: 5 kHz (total of 4ch.)
Note 5)
Note 5)
X0 and X1: 100 µs (5 kHz)
- Input points: 2 ch (Max.)
: 1 kHz (total of 2ch.)
X0 and X1: 100 µs (5 kHz)
40 Hz to 5 kHz (1-point)
40 Hz to 2.5 kHz (2-point)
AFPE214322
type (RS485)
RS485