Section 5: Remote Site Upload/Download - 411Ud Only; General - Fire-Lite 411UD Manual

Digital alarm communicator/transmitters
Hide thumbs Also See for 411UD:
Table of Contents

Advertisement

Section 5: Remote Site Upload/Download - 411UD Only

The 411UD digital communicator may be programmed off site via the public switched telephone
network. Any personal computer with Windows
ble modem and Upload/Download software P/N PK-411UD (available online or on the PK-CD
programming CD) may serve as a Service Terminal. For details on the remote site upload/down-
load software package, refer to the PK-411 Manual. The Upload/Download software allows the
following:
Download of the entire program
Upload of the entire program
Upload current status, system voltages or time
Real-time upload, either continuous or 'snapshot' (one time) of current status or system
voltages
Download new time
CAUTION:
!
CHANGES TO PROGRAM ENTRIES OCCUR AS A RESULT OF THE DOWNLOADING
PROCESS. AFTER SUCCESSFUL DOWNLOADING, MAKE CERTAIN TO PERFORM THE
FOLLOWING STEPS:
1. Manually view programmed entries and compare to intended program data.
2. Test all affected system operations.
3. Immediately correct any problems found.

5.1 General

Any time that the digital communicator is contacted, a secret code (factory default 0000) is verified
between the digital communicator and the Service Terminal. Changing the Secret Code may only
be accomplished at the Service Terminal and subsequently loaded into the control panel. Future
upload or download requests cause verification of the Secret Code by the communicator before
processing of data is allowed. If the Secret Code is not verified, the communicator will terminate
the request immediately.
When the 411UD is communicating with the Service Terminal, one of the communicator's green
Phone Line active LEDs will remain on steady. Upon termination of communication, the green
Phone Line active LED will turn off.
In order to contact the communicator, the following must be true:
The digital communicator may be in any mode of operation including Normal, Program,
Real Time Clock, Troubleshoot or Lamp Test. Downloading is not possible if the
communicator is active during Central Station communications or while testing the phone
lines while in Troubleshoot Mode.
The digital communicator must be unlocked so it can accept a remote upload/download.
Entering mode 8655 (UNLK) will unlock the panel for 30 minutes. Refer to "Panel Unlock
(90)" on page 38 for other programming options.
There cannot be any active communications ongoing with a Central Station receiver.
All active events must be successfully 'kissed-off' by the Central Station(s). The digital
communicator must be in a standby state with no new information waiting to be transmitted
to a Central Station.
Two basic communication mechanisms are supported as follows:
Contact with callback - The Service Terminal calls the digital communicator. The
communicator answers the call, confirms the calling party then hangs-up. The Service
Terminal then waits for a callback from the communicator. After the digital communicator
411 & 411UD Manual — P/N LS10105-000GE-E:A 1/29/2014
PROGRAM DOWNLOAD
®
XP or greater, with a 1200 Baud Hayes compati-
47

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

411