Copper Ethernet Port Specifications; 10Base-Fl Fiber Optic Ethernet Port Specifications; Fiber Optic Ethernet Port Specifications - Siemens RUGGEDCOM RS910 Installation Manual

Hide thumbs Also See for RUGGEDCOM RS910:
Table of Contents

Advertisement

Chapter 4
Technical Specifications
Section 4.3

Copper Ethernet Port Specifications

The following details the specifications for copper Ethernet ports that can be ordered with the RS910.
Order Code
Speed
TX
10/100TX
TX01
10/100TX
e
Auto-negotiating.
f
Shielded or unshielded.
g
Auto-crossover and auto-polarity.
h
Typical distance. Dependent on the number of connectors and splices.
i
RMS 1 minute.
Section 4.4
10Base-FL Fiber Optic Ethernet Port
Specifications
Order
Mode
Code
FL01
MM
Section 4.5

Fiber Optic Ethernet Port Specifications

The following details the specifications for fiber Ethernet ports that can be ordered with the RS910.
NOTE
Order codes are contained within each product when assembled and configured at the factory. Refer to
the ROS User Guide for the RS910 for information on how to obtain the factory configuration data.
NOTE
• All optical power numbers are listed as dBm averages. To convert from average to peak add 3 dBm.
To convert from peak to average, subtract 3 dBm.
• Maximum segment length is greatly dependent on factors such as fiber quality, and the number
of patches and splices. Consult a Siemens sales associate when determining maximum segment
distances.
20
e
Connector
DB9
RJ45
Cable
Tx λ
Connector
Type
(typ.)
Type
(µm)
(nm)
62.5/125
ST
50/125
e
f
Duplex
Cable Type
FDX/HDX
> Category 5
FDX/HDX
> Category 5
Tx min
Tx max
(dBm)
(dBm)
-16
-9
850
-19.8
-12.8
Wiring
Maximum
g
h
Standard
Distance
TIA/EIA
100 m (328 ft)
T568A/B
TIA/EIA
100 m (328 ft)
T568A/B
Rx
Rx
Distance
Sensitivity
Saturation
(typ.)
(dBm)
(dBm)
(km)
-34
-11.2
Copper Ethernet Port Specifications
RUGGEDCOM RS910
Installation Guide
i
Isolation
1.5 kV
1.5 kV
Power
Budget
(dB)
18
2
14.2