UNIT SIZE 588A
NOMINAL CAPACITY (tons)
OPERATING WEIGHT (lb)
Without Base Rail
With Optional Base Rail
COMPRESSOR
Type
Quantity
REFRIGERANT
Charge (lb)
REFRIGERANT METERING DEVICE
CONDENSER COIL
Face Area (sq ft)
Rows...Fins/in.
CONDENSER FAN
Nominal Airflow (cfm)
Nominal Speed (rpm)
Diameter x Width (in.)
Motor Hp
EVAPORATOR COIL
Face Area (sq ft)
Rows...Fins/in.
EVAPORATOR FAN
Nominal Airflow (cfm)
Nominal Speed (rpm)
Diameter x Width (in.)
Motor Hp (single-phase)
(three-phase)
FURNACE SECTION*
Burner Orifice No. (Qty...drill size)
Natural Gas
Burner Orifice No. (Qty...drill size)
Propane Gas
RETURN-AIR FILTERS (in.)†
Throwaway
UNIT SIZE 588A
NOMINAL CAPACITY (tons)
OPERATING WEIGHT (lb)
Without Base Rail
With Optional Base Rail
COMPRESSOR
Type
Quantity
REFRIGERANT
Charge (lb)
REFRIGERANT METERING DEVICE
CONDENSER COIL
Face Area (sq ft)
Rows...Fins/in.
CONDENSER FAN
Nominal Airflow (cfm)
Nominal Speed (rpm)
Quantity...Diameter (in.)
Motor Hp
EVAPORATOR COIL
Face Area (sq ft)
Rows...Fins/in.
EVAPORATOR FAN
Nominal Airflow (cfm)
Nominal Speed (rpm)
Diameter x Width (in.)
Motor Hp (single-phase)
(three-phase)
FURNACE SECTION*
Burner Orifice No. (Qty...drill size)
Natural Gas
Burner Orifice No. (Qty...drill size)
Propane Gas
RETURN-AIR FILTERS (in.)†
Throwaway
*Based on an altitude of 0-2000 ft.
†Required field-supplied filter sizes are based on the larger of the ARI-rated (Air Conditioning & Refrigeration Institute) cooling airflow or the heating
airflow at a velocity of 300 ft/min for throwaway type. Air filter pressure drop for non-standard filters must not exceed 0.08 in. wg.
**Sq inch. Filter is mounted external to unit.
SPECIFICATIONS (cont)
042100
042120
3
1
3
1
2
2
387
387
411
411
Reciprocating
1
5.20
5.20
7.04
7.04
2...17
2...17
1900
1900
1050
1050
1...18
1...18
1
1
4
4
3.33
3.33
3...15
3...15
1400
1400
1100
1100
10 x 10
10 x 10
3
3
4
4
3
3
4
4
2...30
3...32
2...40
3...42
24 x 24
24 x 24
060080
060100
5
5
453
465
477
489
Hermetic Scroll
1
R-22
7.00
7.00
Fixed Orifice Metering Device
8.67
8.67
2...17
2...17
2400
2400
1050
1050
1...20
1...20
1
1
3
3
4.44
4.44
4...15
4...15
1995
1995
1100
1100
10 x 10
10 x 10
1
1
1
1
2...32
2...30
2...42
2...40
24 x 30
24 x 30
12
048080
048100
4
4
414
426
438
450
Hermetic Scroll
1
R-22
6.50
6.50
Fixed Orifice Metering Device
8.67
8.67
2...17
2...17
2400
2400
1050
1050
1...20
1...20
1
1
4
3
4.44
4.44
3..15
3...15
1600
1600
1100
1100
10 x 10
10 x 10
3
3
4
4
3
3
4
4
2...32
2...30
2...42
2...40
24 x 30
24 x 30
060120
060140
5
5
465
465
489
489
7.00
7.00
8.67
8.67
2...17
2...17
2400
2400
1050
1050
1...20
1...20
1
1
3
3
4.44
4.44
4...15
4...15
1995
1995
1100
1100
10 x 10
10 x 10
1
1
1
1
3...32
3...31
3...42
3...40
24 x 30
960**
048120
048140
4
4
426
426
450
450
6.50
6.50
8.67
8.67
2...17
2...17
2400
2400
1050
1050
1...20
1...20
1
1
3
3
4.44
4.44
3...15
3...15
1600
1600
1100
1100
10 x 10
10 x 10
3
3
4
4
3
3
4
4
3...32
3...31
3...42
3...40
24 x 30
816**