Pentair Fleck 6700XTR Service Manual page 15

Hide thumbs Also See for Fleck 6700XTR:
Table of Contents

Advertisement

11.
Regeneration Cycle Step Programming
This program step programs the Regeneration Cycle step times 1 through 5. Please refer to the chart below
for regenerant flow default cycle steps and times..
.
.
.
.
.
.
Regenerant Flow
Cycle 1
.
Down Flow
Back Wash
.
.
Back Wash Filter
Back Wash
.
.
UF Back Wash
Backwash
.
.
Down Flow Double
Back Wash
.
Backwash
.
Up Flow
Brine Rinse
.
.
Upflow Variable Fill
Brine Rinse
12.
Media Volume
This program step sets the volume of the media in the resin tank..
— Press the Shift button to select the digit you want to modify..
— Press the Up or Down buttons to adjust this value..
— Press the Extra Cycle button.
13.
Salt Dosage
This program step sets the salt dosage in the unit..
— Press the Shift button to select the digit you want to modify..
— Press the Up or Down buttons to adjust this value..
— Press the Extra Cycle button.
14.
Brine Line Flow Control Size
This program step allows the selection of the desired brine line flow control size in the unit (must match
physical brine line flow control)..
— Press the Up or Down buttons to adjust this value..
— Press the Extra Cycle button.
15.
Auxiliary Relay Output
The next two displays are part of a series of settings used to program the optional relay output. The first.
setting turns the output on/off during regeneration only. The second turns the output on during service only,
every time a set volume of water used has accumulated..
NOTE: When auxiliary outputs are in the OFF (default) setting, press the Up or Down buttons to set
CAUTION: Before entering Master Programming, please contact your local professional water dealer.
Time
Cycle 2
Time
Brine
10.
& Slow
1 Hour
Minutes
Rinse
15.
Draw
0
Minutes
Brine
10.
& Slow
1 Hour
Minutes
Rinse
Brine
10.
& Slow
1 Hour
Minutes
Rinse
Back
60
10
Wash
60.
Variable
Pause
minutes
Master Programming Mode
Cycle 3
Time
Cycle 4
Rapid
10.
Brine Tank Fill
Rinse
Minutes
Settling
10.
Refill
Rinse
Minutes
Rapid
10.
Brine Tank Fill
Rinse
Minutes
Back
10.
Rapid Rinse
Wash
Minutes
Rapid
10.
Brine Tank Fill
Rinse
Minutes
Brine
60.
Back Wash
Rinse
Minutes
Time
Cycle 5
12 Minutes
N/A
N/A
0
12 Minutes
N/A
10 Minutes
Brine Tank Fill
12 Minutes
N/A
12 Minutes
Rapid Rise
Page 15
Time
N/A
N/A
N/A
12 Minutes
N/A
10 Minutes

Hide quick links: