  • Page 2: Table Of Contents

    CONTENT OVERALL DESCRIPTIONS 1-1. Names and Functions of Parts 1-2. Names and Functions of Keys FUNCTIONS BASIC OPERATION DEFAULT SETTINGS IN FACTORY SPECIFICATIONS ADJUSTMENT OF THE FEED GAP DAILY CARE ERRORS AND REMEDIAL MEASURES ACCESSORIES & OPTIONS...
  • Page 3: Overall Descriptions

    1.OVERALL DESCRIPTIONS 1-1. Names and Functions of Parts Front View ① ① ① ① Hopper The counted notes are placed in it. ② ② ② ② Auxiliary Hopper Plates Used for leading the notes to the feeding mechanism. ③ ③ ③ ③ Keys Refer to page 5 for description of each key.
  • Page 4 Rear View ⑥ ⑥ ⑥ ⑥ Thickness Adjustment Knob Used to adjust the Feed Gap to make the counting smooth. To widen the Feed Gap by turning the Knob towards “+” sign, and to narrow the Feed Gap towards “-” sign. ⑦...
  • Page 5: Names And Functions Of Keys

    1-2. Names and Functions of Keys By this key, each counted result will be added to the previous one. Auto start and Manual start can be selected by this key. This key can clear counted result, batch number or exit denomination setting in that order.
  • Page 6: Functions

    FUNCTIONS ADD Function Press ADD key to turn on or off this function. ADD will be shown on display when it’s Every time the machine has completed counting, the Display will show accumulated count. Press C key to clear the accumulated count. Auto and Manual Start Functions Auto Start and Manual Start can be chosen by pressing MNL key.
  • Page 7 Counting Speed Function SPEED An appropriate speed can be chosen by pressing this key, changeable in three levels (Slow, Normal, Fast): Speed-1 900 notes/min. (Slow) Speed-11 (Default) 1200 notes/min. (Normal) 1600 notes/min. (Fast) Speed -111 BATCH Function Machine will count notes by batch if batch function is activated. After counting every BATCH batch of notes, the machine will stop.
  • Page 8 Double Feeding Detection Function Machine detects Double Feeding by DEN function. The detection level can be selected by DEN key depending on the density of the notes. Four different levels can be chosen by pressing DEN key in the following sequence: DEN-1 →...
  • Page 9 MG Detection Function (option) This function is to detect the magnetism on notes. Through this function, the machine can detect counterfeit notes without magnetism. When a counterfeit note is detected, the machine will stop and show the error message “CF2”. The suspected note is the last one in the stacker.
  • Page 10 Value Calculation Function VALUE This function is to select the denomination of notes to be counted and check total value after counting notes of the selected denomination. “$” key: DNMNT 1→2→5→10→20→50→100→blank(off) Step 1: Switch to the denomination of notes you are going to count by pressing “$” key. Step 2: Count notes of the selected denomination.
  • Page 11: Basic Operation

    3. BASIC OPERATION Step 1. Turn on the Power Switch. Step 2. Set batch number by pressing 0-9 keys if necessary. Step 3. Set Counting Speed, Auto or Manual Start function, DEN, UVD, MGD functions if necessary. Step 4. Load the notes onto the Hopper and set the right position to the Auxiliary Plates.
  • Page 12: Specifications

    5. SPECIFICATIONS Ambient Temperature 40℃ Ambient Humidity Feeding System Roller Friction System Hopper Capacity 400 notes Stacker Capacity 200 notes Size of Countable Note 50×90 110×185(mm) Thickness of Countable Note 0.05 0.2(mm) Batch Number Displayed Three Digits (LCD) Counting Number Displayed Seven Digits (LCD) Message Displayed Three Digits (LCD)
  • Page 13: Daily Care

    7. DAILY CARE Clean the following Sensors with a brush periodically Hopper Sensor and Stacker Sensor Counting Sensors...
  • Page 14: Errors And Remedial Measures

    8. ERRORS AND REMEDIAL MEASURES When an error occurs during counting, the LCD Display will flash the error code. Clear the error in accordance with the following procedures. Error Cause of Error Remedial Measures Code Hopper Sensor is covered. Remove what is covering the Hopper Sensor. 1, One or both of Counting Sensors 1, Replace the damaged Counting Sensor.
  • Page 15: Accessories & Options

    9. ACCESSORIES & OPTIONS 9-1 Accessories 1. Power Cable……………..1 2. Instruction Manual………1 3. Brush…………………….1 9-2 Options 1. External Display An option of the External Display is available, which will show the counting results synchronizingly when connected to the RS232 interface of the banknote counter. 2.