Control Commands Via Lan - Panasonic PT-JX200HBU Operating Instrucctions

Table of Contents

Advertisement

Channel
Control details
19
20
Memory Viewer
21
22
Note
f If the projector is operated with the remote control or by the control command while controlling the projector using the Art-Net function, the
setting of the DMX controller and the computer application may be different from the projector status. In this case, set "Lock" of channel 11
to "Operation not available" and then set back to "Operation available" so that the controls of all channels are applied to the projector.

Control commands via LAN

When the projector is connected to a computer via a LAN, the computer can use control commands to operate the
projector and query its status.
When web control administrator rights password is set (Protect mode)
Connecting method
1)
Obtain the IP address and port number (Initial set value = 1024) of the projector and request a
connection to the projector.
f Both the IP address and the port number can be obtained from the menu screen of the projector.
IP address
Port number
2)
Check the response from the projector.
Data section
Command
"NTCONTROL"
example
(ASCII string)
Data length
f Mode: 1 = Protect mode
3)
Generate a 32-byte hash value from the following data using MD5 algorithm.
f "xxxxxx:yyyyy:zzzzzzzz"
xxxxxx
yyyyy
zzzzzzzz
Command transmission method
Transmit using the following command formats.
142 - ENGLISH
Chapter 7 Appendix — Technical information
Performance
No operation from the <6>
button on remote control
Input from the <6> button on
remote control
No operation from the <7>
button on remote control
Input from the <7> button on
remote control
No operation from the <8>
button on remote control
Input from the <8> button on
remote control
No operation from the <9>
button on remote control
Input from the <9> button on
remote control
Obtain from the main menu → [NETWORK] → [NETWORK STATUS]
Obtain from the main menu → [NETWORK] → [NETWORK CONTROL] → [COMMAND PORT]
Blank
' '
0x20
9 bytes
1 byte
Administrator rights user name for the web control (default user name is "admin1")
Password of above administrator rights user (default password is "panasonic")
8-byte random number obtained in Step 2)
Parameter
Default value
0-127
128-255
0-127
128-255
0-127
128-255
0-127
128-255
Mode
Blank
Random number section
'1'
' '
0x31
0x20
(ASCII code hex number)
1 byte
1 byte
Remark
0
Corresponds to the direct
playback function of Memory
Viewer.
The number buttons on remote
0
control mentioned on the left
indicate the following.
g Number (<1> - <6>) buttons
when operating by the supplied
0
remote control
g Number (<0> - <9>) buttons
when operating by the browser
remote control of Wireless
Manager ME6.3
0
Termination
"zzzzzzzz"
8 bytes
symbol
(CR)
0x0d
1 byte

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pt-jx200hwu