Completing Setup From The Noc - Paradyne FrameSaver DSL 9788 Router Installation Instructions Manual

Bridge/router endpoint document number 9788-a2-gn11-00
Table of Contents

Advertisement

3. Specify TS Access if a Troubleshooting (TS) DLCI or Virtual Circuit (VC) is being
set up for remote access by the service provider. The default is 0,35.
4. Select Create a Dedicated Network Management Link to set up for permanent
remote access by the NOC. Enter a DLCI, VPI, and VCI at the resulting prompts.
5. Select the Ethernet Management Options Screen to go directly to the Ethernet
Management Options screen. The interface (Status) is already enabled.
— Enter the IP Address (for example, 10.101.51.253) and Subnet Mask (for
example, 255.255.255.0) for the Ethernet interface.
— Enter the Default Gateway Address (the IP Address that will be used for
packets without a specified route).
— Press the Esc key to return to the Easy Install screen.
6. Change Network 1 DSL Line Rate (Kbps), if desired. The default is AutoRate.
7. Save the configuration and return to the Configuration Edit/Display menu.

Completing Setup From the NOC

Procedure
1. Access the router on the TS Management Link that was set up at the remote site in
Using the Easy Install Feature
Step 4
of
2. Ping the router five times within five seconds. The router automatically provisions
the TS Access VC and accepts the destination IP address of the Ping as its
temporary IP address, which is used on the management VC interface.
3. If necessary, open a Telnet session and configure any specific configuration options
that require input or changes from default settings. Create all customer VCs,
including internal DLCIs and VPI/VCIs on the DSL interface, and cross-connect the
DLCIs to the VCCs.
.
18

Advertisement

Table of Contents
loading

This manual is also suitable for:

9720

Table of Contents