Unit functions
Printed circuit board
1
2
3
Electrical connection, printed circuit board
5
7
3
6
2
Vacuum hose connection
1 Control lamp, filter status
2 Housing for control printed circuit board
3 Mains connection cable
4 Earth connection plug
5 Unit switch
6 Vacuum hose on the printed circuit board
7 Vacuum hose connection
Page 10 / 25
5
4
Replace the printed circuit board
When installing the printed circuit board with
housing (2) ensure that the vacuum hose (6) is
correctly pushed onto the connection (7). The
vacuum sensor on the printed circuit board
measures the vacuum in the suction system.
The control lamp lights up if the vacuum increases
(filter bag full). If the printed circuit board is
defective, it must be replaced together with the
housing (2).
New Unit Information 02.2004
CV 30/1, CV 38/1