Lenovo S2200 Product Manual
Hide thumbs Also See for S2200:

Advertisement

Lenovo Storage S2200
Lenovo Press Product Guide
The Lenovo® Storage S2200 (as shown in the following figure) provides simplicity, speed, scalability,
security, and high availability for small to large businesses. The S2200 SAN array delivers
enterprise-class storage management technology in an affordable solution with a wide choice of host
connectivity options, flexible drive configurations, and enhanced data management features.
The S2200 is a perfect fit for small offices and remote and branch offices of large enterprises that need a
primary storage solution that supports general purpose workloads, such as file and print serving, web
serving, email and collaboration, and small databases. The S2200 is also well-suited for secure archive
storage or a low-cost backup solution.
Figure 1. Lenovo Storage S2200
The S2200 offers the flexible choice of 6/12 Gb SAS, 1/10 Gb iSCSI, and 4/8 Gb Fibre Channel (FC) host
connectivity protocols. The Converged Network Controller (CNC) design of the S2200 makes the
selection of iSCSI or FC host connectivity as simple as attaching corresponding transceivers or
Direct-Attach Copper (DAC) cables to the SFP/SFP+ ports on the RAID controller.
The S2200 supports up to 96 drives with up to three external expansion enclosures. It also offers flexible
drive configurations with the choice of 2.5-inch and 3.5-inch drive form factors, 10 K or 15 K rpm SAS and
7.2 K rpm NL SAS hard disk drives (HDDs) and self-encrypting drives (SEDs), and SAS solid-state drives
(SSDs). The S2200 can be scaled up to 288 TB of raw storage capacity.
Did you know?
The S2200 supports Intelligent Real-time Tiering capabilities that help optimize system performance,
reduce costs, and simplify management. The base software includes the ability to move data dynamically
between SAS HDDs that are optimized for cost per IOPS and NL SAS HDDs that are optimized for cost
per GB. With the optional software license, the S2200 supports hybrid tiering across HDDs and SSDs.
The S2200 can be upgraded to the Lenovo Storage S3200 by replacing the RAID controllers in the
controller enclosure during a planned offline maintenance window without the need to migrate or move
data and re-configure the attached hosts. The new S3200 RAID controller recognizes the array
configuration and preserves the controller's host port parameters (for example, FC WWN).
The S2200 supports battery-free cache protection, which reduces maintenance costs and provides
permanent backup of unwritten cache data if there is a power failure.
Lenovo Storage S2200
1

Advertisement

Table of Contents
loading

Summary of Contents for Lenovo S2200

  • Page 1 The S2200 is a perfect fit for small offices and remote and branch offices of large enterprises that need a primary storage solution that supports general purpose workloads, such as file and print serving, web serving, email and collaboration, and small databases.
  • Page 2: Key Features

    Lenovo Storage E1012 expansion enclosure (12x LFF drives each) or up to 96 SFF drives per system with the attachment of Lenovo Storage E1024 expansion enclosure (24x SFF drives each) to satisfy growing needs for storage capacity and performance.
  • Page 3 The S2200 storage system offers high levels of system and data availability with the following technologies: Dual-active RAID controllers with low latency cache mirroring  Dual-port drives (HDDs and SSDs) with automatic drive failure detection and rapid RAID rebuild with ...
  • Page 4 The S2200 storage capabilities can be expanded with optional licensed functions. Each optional S2200 function is licensed on a per-system basis and covers controller enclosure and all attached expansion units. The following optional licensed functions are available: Intelligent Real-time Tiering for SSDs ...
  • Page 5 Components The following figure shows the front of the S2200 SFF chassis and E1024 drive expansion enclosure. Figure 2. Front view of the S2200 SFF chassis and E1024 drive enclosure The following figure shows the front of the S2200 LFF chassis and E1012 drive expansion enclosure.
  • Page 6 The following figure shows the rear of the S2200 with FC or iSCSI host interfaces with dual RAID controllers. Single RAID controller configurations also are supported. Figure 4. Rear view of the S2200 with FC or iSCSI host interfaces The following figure shows the rear of the S2200 with SAS host interfaces with dual RAID controllers.
  • Page 7: Technical Specifications

    The following figure shows the rear of the E1012 and E1024 drive enclosures with dual I/O expansion modules. Single I/O module configurations also are supported with the single-controller S2200. Figure 6. Rear view of the E1012 and E1024 drive enclosures Note: The RAID controllers (as shown in Figure 4 and Figure 5) and expansion modules (as shown in Figure 6) include extra service ports with a specialized connector.
  • Page 8 Storage capacity Up to 288 TB (48x 6 TB NL SAS HDDs) Host connectivity S2200 SAS controller: 2x 6/12 Gb SAS host ports (Mini-SAS HD, SFF-8644) S2200 FC and iSCSI controller: 2x SFP/SFP+ CNC host ports CNC host port options (per RAID controller): 2x 1 Gb iSCSI SFP (1 Gb speed, UTP, RJ-45) ...
  • Page 9: Controller Enclosures

    4-hour response time, 1-year or 2-year warranty extensions, Hard Drive Retention. Dimensions S2200 LFF and E1012: Height: 87 mm (3.4 in), width: 447 mm (17.6 in), depth: 523 mm  (20.6 in) S2200 SFF and E1024: Height: 89 mm (3.5 in), width: 447 mm (17.6 in), depth: 519 mm ...
  • Page 10: Raid Controller Modules

    HBA installed. Each S2200 SAS Controller has two 6/12 Gb SAS ports with Mini-SAS HD (SFF-8644) connectors. S2200 FC and iSCSI RAID Controllers provide SAN based iSCSI or FC connectivity to the hosts with a supported software initiator or HBA installed. Each S2200 FC and iSCSI Controller has a built-in CNC, which has two SFP/SFP+ ports.
  • Page 11 FC and iSCSI controller host connectivity options Lenovo Storage S2200/S3200 1G RJ45 iSCSI SFP+ Module 1 pack 00WC086 AT2C Lenovo Storage S2200/S3200 10G SW Optical iSCSI SFP+ Module 1 pack 00WC087 AT2A Lenovo Storage S2200/S3200 8G Fibre Channel SFP+ Module 1 pack 00WC088 AT28...
  • Page 12: Expansion Enclosures

    E1012 and E1024 can be configured with one or two expansion modules. Single module configurations can be upgraded to dual module configurations non-disruptively. The number of expansion modules in the E1012 or E1024 must match the number of RAID controllers in the S2200. Lenovo Storage S2200...
  • Page 13 OUT. These ports are used for connections to the S2000 and for daisy chaining the E1012 and E1024 enclosures between each other. The expansion port on the S2200 controller is connected to the IN port on the expansion module. The OUT port on the expansion module is connected to the IN port on the expansion module in the adjacent enclosure, and so on.
  • Page 14: Drive Options

    * One cable per SAS expansion module Drive options The S2200 LFF chassis and the E1012 expansion enclosure support up to 12 LFF hot-swap drives. The S2200 SFF chassis and the E1024 expansion enclosure support up to 24 SFF hot-swap drives.
  • Page 15: Software Options

    The following table lists drive options for the S2200 SFF chassis and the E1024 expansion enclosure. Table 7. LFF drive options Feature code Maximum (MTM qty per one Part 6411-HC1, S2200 SFF number 6411-HC3) or E1024 Description 2.5-inch SAS hot-swap HDDs Lenovo Storage 2.5"...
  • Page 16: Power Cables

    AT2J Power cables The S2200, E1012, and E1024 ship standard with two 4.3 m, 10 A/100 - 250 V, C13 to IEC 320-C14 Rack Power Cables. Other power cable options are also available. The part numbers and feature codes to order them (two power cables are required per each S2200, E1012, and E1024) are listed in the following table.
  • Page 17: Operating Environment

    United Kingdom 10A/250V C13 to BS 1363/A 2.8m line cord 39Y7923 6215 Operating environment The S2200, E1012, and E1024 are supported in the following environment: Air temperature:  Operating: 5 °C - 40 °C (41 °F - 104 °F); decrease the maximum ambient temperature by 3.3 °C ...
  • Page 18: Warranty Options

    Lenovo system. In the unlikely event of a hard drive failure, you retain possession of your hard drive while Lenovo replaces the failed drive part. Your data stays safely on your premises, in your hands.
  • Page 19: Regulatory Compliance

    Lenovo provides end-to-end storage compatibility testing to deliver interoperability throughout the network. The S2200 supports attachment to Lenovo System x®, ThinkServer®, and Flex System™ hosts by using SAS, iSCSI, Fibre Channel, or Fibre Channel over Ethernet (FCoE) (via the FCoE gateway) storage connectivity protocols.
  • Page 20 With software iSCSI initiators, any supported 1 Gb Ethernet or 10 Gb Ethernet adapter for System x, ThinkServer, and Flex System is compatible with the S2200 iSCSI storage. For more information about hardware iSCSI initiators (iSCSI HBAs), see the S2200 support page on the Lenovo support web site ( http://support.lenovo.com) or ask a Lenovo representative.
  • Page 21 Table 12. S2200 FC adapter interoperability (Part 2) Description Part number System x - 8 Gb FC Brocade 8Gb FC Dual-port HBA 46M6050 Brocade 8Gb FC Single-port HBA 46M6049 Emulex 8Gb FC Dual-port HBA 42D0494 Emulex 8Gb FC Single-port HBA...
  • Page 22 Lenovo support web site (http://support.lenovo.com) or ask a Lenovo representative. Networking switches The following table lists the Ethernet and Fibre Channel rack mount switches that are offered by Lenovo that can be used in S2200 storage solutions. Table 13. Ethernet and Fibre Channel rack mount switches...
  • Page 23 Cisco Nexus B22 Fabric Extender with FET bundle for Flex System* 94Y5355 Converged 10 GbE and 8 Gb FC (FCoE gateways) Lenovo Flex System Fabric CN4093 10Gb Converged Scalable Switch 00FM510 Converged 10 GbE and 16 Gb FC (FCoE gateways)
  • Page 24: Rack Cabinets

    Rack cabinets The following table lists the rack cabinets that are offered by Lenovo that can be used in S2200 storage solutions. Table 15. Rack cabinets Description Part number 11U Office Enablement Kit 201886X 25U Standard Rack 93072RX 25U Static S2 Standard Rack...
  • Page 25: Power Distribution Units

    Power distribution units The following table lists the the power distribution units (PDUs) that are offered by Lenovo that can be used in S2200 storage solutions. Table 16. Power distribution units (Part 1) Description Part number Switched and Monitored PDUs...
  • Page 26 46M4131 0U 12 C19/12 C13 60A 3 Phase PDU 46M4140 0U 12 C19/12 C13 32A 3 Phase PDU 46M4143 For more information, see the list of Product Guides in the Power infrastructure category at this website: http://lenovopress.com/systemx/power Lenovo Storage S2200...
  • Page 27: Uninterruptible Power Supply Units

    Uninterruptible power supply units The following table list the uninterruptible power supply (UPS) units that are offered by Lenovo that can be used in S2200 storage solutions. Table 17. Uninterruptible power supply units Description Part number RT1.5kVA 2U Rack or Tower UPS (100-125VAC) 55941AX RT1.5kVA 2U Rack or Tower UPS (200-240VAC)
  • Page 28: Lenovo Financial Services

    For you, this dedication provides a high-quality, easy, and positive financing experience. For your region specific offers, ask your Lenovo sales representative or your technology provider about the use of Lenovo Financial Services. For more information, see the following Lenovo website: http://www.lenovo.com/services_warranty/us/en/financial_services.html...
  • Page 29 Web sites. The materials at those Web sites are not part of the materials for this Lenovo product, and use of those Web sites is at your own risk. Any performance data contained herein was determined in a controlled environment.
  • Page 30 Trademarks Lenovo, For Those Who Do and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. These and other Lenovo trademarked terms are marked on their first occurrence in this information with the appropriate symbol (® or ™), indicating US registered or common law trademarks owned by Lenovo at the time this information was published.

Table of Contents