Lenovo S2200 Product Manual
Hide thumbs Also See for S2200:

Advertisement

Lenovo Storage S2200
Product Guide
The Lenovo Storage S2200 (shown in the following figure) provides simplicity, speed, scalability, security,
and high availability for small to large businesses. The S2200 SAN array delivers enterprise-class storage
management technology in an affordable solution with a wide choice of host connectivity options, flexible
drive configurations, and enhanced data management features.
The S2200 is a perfect fit for small offices and remote and branch offices of large enterprises that need a
primary storage solution that supports general purpose workloads, such as file and print serving, web
serving, email and collaboration, and small databases. The S2200 is also well-suited for secure archive
storage or a low-cost backup solution.
Figure 1. Lenovo Storage S2200
The S2200 offers the flexible choice of 6/12 Gb SAS, 1/10 Gb iSCSI, and 4/8 Gb Fibre Channel (FC) host
connectivity protocols. The Converged Network Controller (CNC) design of the S2200 makes the selection
of iSCSI or FC host connectivity as simple as attaching corresponding transceivers or Direct-Attach Copper
(DAC) cables to the SFP/SFP+ ports on the RAID controller.
The S2200 supports up to 96 drives with up to three external expansion enclosures. It also offers flexible
drive configurations with the choice of 2.5-inch and 3.5-inch drive form factors, 10 K or 15 K rpm SAS and
7.2 K rpm NL SAS hard disk drives (HDDs) and self-encrypting drives (SEDs), and SAS solid-state drives
(SSDs). The S2200 can be scaled up to 480 TB of raw storage capacity.
Did you know?
The S2200 supports Intelligent Real-time Tiering capabilities that help optimize system performance, reduce
costs, and simplify management. The base software includes the ability to move data dynamically between
SAS HDDs that are optimized for cost per IOPS and NL SAS HDDs that are optimized for cost per GB. With
the optional software license, the S2200 supports hybrid tiering across HDDs and SSDs.
The S2200 can be upgraded to the Lenovo Storage S3200 by replacing the RAID controllers in the
controller enclosure during a planned offline maintenance window without the need to migrate or move data
and re-configure the attached hosts. The new S3200 RAID controller recognizes the array configuration and
preserves the controller's host port parameters (for example, FC WWN).
The S2200 supports battery-free cache protection, which reduces maintenance costs and provides
permanent backup of unwritten cache data if there is a power failure.
Click here to check for updates
Lenovo Storage S2200
1

Advertisement

Table of Contents
loading

Summary of Contents for Lenovo S2200

  • Page 1 The S2200 is a perfect fit for small offices and remote and branch offices of large enterprises that need a primary storage solution that supports general purpose workloads, such as file and print serving, web serving, email and collaboration, and small databases.
  • Page 2: Key Features

    Lenovo Storage E1012 expansion enclosure (12x LFF drives each) or up to 96 SFF drives per system with the attachment of Lenovo Storage E1024 expansion enclosure (24x SFF drives each) to satisfy growing needs for storage capacity and performance.
  • Page 3 The S2200 storage system offers high levels of system and data availability with the following technologies: Dual-active RAID controllers with low latency cache mirroring Dual-port drives (HDDs and SSDs) with automatic drive failure detection and rapid RAID rebuild with global hot spares...
  • Page 4: Components And Connectors

    SNMP and email notifications. Components and connectors The following figure shows the front of the S2200 SFF chassis and E1024 drive expansion enclosure. Figure 2. Front view of the S2200 SFF chassis and E1024 drive enclosure The following figure shows the front of the S2200 LFF chassis and E1012 drive expansion enclosure.
  • Page 5 The following figure shows the rear of the S2200 with FC or iSCSI host interfaces with dual RAID controllers. Single RAID controller configurations also are supported. Figure 4. Rear view of the S2200 with FC or iSCSI host interfaces The following figure shows the rear of the S2200 with SAS host interfaces with dual RAID controllers. Single RAID controller configurations also are supported.
  • Page 6: System Specifications

    Figure 6. Rear view of the E1012 and E1024 drive enclosures Note: The RAID controllers (as shown in Figure 4 and Figure 5) and expansion modules (as shown in Figure 6) include extra service ports with a specialized connector. These ports are reserved for use by a Lenovo service technician.
  • Page 7 Up to 480 TB (48x 10 TB NL SAS HDDs) Host connectivity S2200 SAS controller: 2x 6/12 Gb SAS host ports (Mini-SAS HD, SFF-8644) S2200 FC and iSCSI controller: 2x SFP/SFP+ CNC host ports CNC host port options (per RAID controller):...
  • Page 8 SFF chassis: Height: 89 mm (3.5 in), width: 447 mm (17.6 in), depth: 519 mm (20.5 in) Weight S2200 LFF: Minimum: 17.7 kg (39.0 lb); Maximum: 27.5 kg (60.6 lb) S2200 SFF: Minimum: 17.8 kg (39.2 lb); Maximum: 24.3 kg (53.6 lb) E1012: Minimum: 16.8 kg (37.0 lb);...
  • Page 9: Controller Enclosures

    Controller enclosures The following table lists the relationship models of the S2200 chassis. Product availability: Relationship models of the Lenovo Storage S2200 listed in this section are withdrawn and no longer available for ordering. Table 2. Part numbers for ordering S2200 relationship models...
  • Page 10 The following table lists the TopSeller models of the S2200 chassis. Note: S2200 TopSeller models are not available for ordering in North America (United States and Canada) Product availability: TopSeller models of the Lenovo Storage S2200 listed in this section are withdrawn and no longer available for ordering.
  • Page 11: Raid Controller Modules

    S2200 FC and iSCSI RAID Controllers S2200 SAS RAID Controllers provide direct SAS attachment for up to two hosts with a supported SAS HBA installed. Each S2200 SAS Controller has two 6/12 Gb SAS ports with Mini-SAS HD (SFF-8644) connectors.
  • Page 12: System Upgrades

    FC and iSCSI controller host connectivity options Lenovo Storage S2200/S3200 1G RJ45 iSCSI SFP+ Module 1 pack 00WC086 AT2C Lenovo Storage S2200/S3200 10G SW Optical iSCSI SFP+ Module 1 pack 00WC087 AT2A Lenovo Storage S2200/S3200 8G Fibre Channel SFP+ Module 1 pack...
  • Page 13: Expansion Enclosures

    OUT. These ports are used for connections to the S2000 and for daisy chaining the E1012 and E1024 enclosures between each other. The expansion port on the S2200 controller is connected to the IN port on the expansion module. The OUT port on the expansion module is connected to the IN port on the expansion module in the adjacent enclosure, and so on.
  • Page 14 Feature code Max qty per number (MTM 6411- one E1012 or HC3) E1024 Expansion modules Lenovo Storage Expansion SAS IO Module 00WC085 AT27 SAS expansion connectivity cables External MiniSAS 8088/MiniSAS 8088 1m cable 00WE755 AT1B External MiniSAS 8088/MiniSAS 8088 0.6m cable...
  • Page 15 Drives The S2200 LFF chassis and the E1012 expansion enclosure support up to 12 LFF hot-swap drives. The S2200 SFF chassis and the E1024 expansion enclosure support up to 24 SFF hot-swap drives. The following table lists drive options for the S2200 LFF chassis and the E1012 expansion enclosure.
  • Page 16 The following table lists drive options for the S2200 SFF chassis and the E1024 expansion enclosure. Table 8. SFF drive options Description Part Feature code Max qty per number (MTM 6411-HC1, one S2200 SFF 6411-HC3) or E1024 2.5-inch SAS hot-swap HDDs Lenovo Storage 2.5"...
  • Page 17: Power Cables

    Snapshots: up to 512 targets Asynchronous replication The following table lists the Feature on Demand (FoD) upgrades for the S2200 to enable optional software features. Each optional S2200 function is licensed on a per-system basis and covers both controller enclosure and all attached expansion units.
  • Page 18: Physical Specifications

    Power cables The S2200, E1012, and E1024 ship standard with two 4.3 m, 10 A/100 - 250 V, C13 to IEC 320-C14 Rack Power Cables. Other power cable options are also available. The part numbers and feature codes to order them (two power cables are required per each S2200, E1012, and E1024) are listed in the following table.
  • Page 19: Operating Environment

    Noise level: 6.8 bels Warranty The S2200 includes a three-year parts-only warranty with 9x5/next business day (NBD) terms. Lenovo offers the service upgrades through warranty maintenance upgrades and post-warranty maintenance agreements with a well-defined scope of services, including service hours, response time, term of service, and service agreement terms and conditions.
  • Page 20: Regulatory Compliance

    Lenovo system. In the unlikely event of a hard drive failure, you retain possession of your hard drive while Lenovo replaces the failed drive part. Your data stays safely on your premises, in your hands.
  • Page 21 Lenovo Storage S2200/S3200 Interoperability Matrix that can be found on the S2200 Documentation page: http://datacentersupport.lenovo.com/us/en/products/storage/lenovo-storage/s2200/6411/documentation SAS interoperability The SAS adapters that are listed in the following table are compatible with the S2200 SAS storage (direct attach). Table 13. S2200 SAS adapter interoperability Description...
  • Page 22 The S2200 supports FC direct attachments and FC switch based attachments. Brocade and QLogic SAN switches can be used to provide FC connectivity with the S2200 FC storage. The FC adapters that are listed in the following table are compatible with the S2200 FC storage. Table 14. S2200 FC adapter interoperability...
  • Page 23 Networking switches The following table lists the Ethernet and Fibre Channel rack mount switches that are offered by Lenovo that can be used in S2200 storage solutions. Table 15. Ethernet and Fibre Channel rack mount switches Description Part number 1 Gb Ethernet (iSCSI connectivity)
  • Page 24: Rack Cabinets

    VMware vSphere 6.0 Update 2 VMware vSphere 6.0 Update 1 VMware vSphere 6.0 VMware vSphere 5.5 Update 3 VMware vSphere 5.5 Update 2 VMware vSphere 5.5 Other configurations might be supported; for more information, see the S2200/S3200 Interoperability Matrix. Rack cabinets Lenovo Storage S2200...
  • Page 25: Power Distribution Units

    Rack cabinets The following table lists the rack cabinets that are offered by Lenovo that can be used in S2200 storage solutions. Table 17. Rack cabinets Description Part number 25U S2 Standard Rack 93072RX 25U Static S2 Standard Rack 93072PX...
  • Page 26: Uninterruptible Power Supply Units

    DPI 63a Cord (IEC 309 P+N+G) 40K9613 DPI Australian/NZ 3112 Line Cord (32A) 40K9617 DPI Korean 8305 Line Cord (30A) 40K9618 For more information, see the list of Product Guides in the Power Distribution Units category: http://lenovopress.com/servers/options/pdu Uninterruptible power supply units Lenovo Storage S2200...
  • Page 27: Lenovo Financial Services

    Uninterruptible power supply units The following table list the uninterruptible power supply (UPS) units that are offered by Lenovo that can be used in S2200 storage solutions. Table 19. Uninterruptible power supply units Description Part number RT1.5kVA 2U Rack or Tower UPS (100-125VAC) 55941AX RT1.5kVA 2U Rack or Tower UPS (200-240VAC)
  • Page 28: Related Product Families

    Related publications and links For more information, see the following resources: Lenovo Storage S2200 product page: http://www.lenovo.com/systems/storage Lenovo Hardware Configurator: http://lesc.lenovo.com/products/hardware/configurator/bhui/launchNI.wss Lenovo Storage S2200 support: http://support.lenovo.com/us/en/products/Servers/Lenovo-Storage/Lenovo-Storage-S2200 Related product families Product families related to this document are the following: Lenovo Storage...
  • Page 29 Web sites. The materials at those Web sites are not part of the materials for this Lenovo product, and use of those Web sites is at your own risk. Any performance data contained herein was determined in a controlled environment.
  • Page 30 Trademarks Lenovo, the Lenovo logo, and For Those Who Do are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at http://www3.lenovo.com/us/en/legal/copytrade/. The following terms are trademarks of Lenovo in the United States, other countries, or both:...

This manual is also suitable for:

S3200

Table of Contents