Lenovo Storage V3700 V2 and V3700 V2 XP (Machine Type 6535) are members of the Lenovo Storage V
Series family of disk systems. By using IBM Spectrum Virtualize software functions, interoperability, and
management tools, Lenovo Storage V3700 V2 and V3700 V2 XP deliver innovation and new levels of
storage efficiency with ease of use in an entry-level disk system to enable organizations to overcome their
storage challenges.
Lenovo Storage V3700 V2 and V3700 V2 XP storage systems feature two node canisters, with 8 GB cache
per canister, upgradeable to 16 GB per canister (V3700 XP only), in a compact, 2U, 19-inch rack mount
enclosure. 12 Gb SAS (V3700 V2 XP only) and 1 Gb iSCSI connectivity is standard, with an option for
additional 1 Gb iSCSI, 12 Gb SAS, 16 Gb Fibre Channel (FC), or 10 Gb iSCSI or Fibre Channel over
Ethernet (FCoE) connectivity.
Lenovo Storage V3700 V2 and V3700 V2 XP support up to 240 drives with up to nine expansion
enclosures. They also offer flexible drive configurations with the choice of 2.5-in. and 3.5-in. form factors,
10 K or 15 K rpm SAS and 7.2 K rpm NL SAS hard disk drives (HDDs), and SAS solid-state drives (SSDs).
The Lenovo Storage V3700 V2 and V3700 V2 XP enclosures are shown in the following figure.
Figure 1. Lenovo Storage V3700 V2 and V3700 V2 XP SFF (top) and LFF (bottom) enclosures
Did you know?
Lenovo Storage V3700 V2 and V3700 V2 XP provide small and midsized organizations with the ability to
consolidate and share data at an affordable price, while utilizing advanced software capabilities that often
are found in more expensive systems.
Lenovo Storage V3700 V2 and V3700 V2 XP can be scaled up to 960 TB of raw storage capacity.
Lenovo Storage V3700 V2 offers hybrid block storage connectivity with support for 1 Gb iSCSI and 12 Gb
SAS, 10 Gb iSCSI or FCoE, or 16 Gb FC host connectivity at the same time. With Lenovo Storage V3700 V2
XP, 12 Gb SAS, 1 Gb iSCSI, and 10 Gb iSCSI or FCoE or 16 Gb FC can be used simultaneously.
Click here to check for updates
Lenovo Storage V3700 V2 and V3700 V2 XP
1

Advertisement

Table of Contents
loading

Summary of Contents for Lenovo V3700 V2

  • Page 1 Lenovo Storage V3700 V2 offers hybrid block storage connectivity with support for 1 Gb iSCSI and 12 Gb SAS, 10 Gb iSCSI or FCoE, or 16 Gb FC host connectivity at the same time. With Lenovo Storage V3700 V2 XP, 12 Gb SAS, 1 Gb iSCSI, and 10 Gb iSCSI or FCoE or 16 Gb FC can be used simultaneously.
  • Page 2: Key Features

    При обращении используйте промокод AND-PDF и получите скидку. Key features The Lenovo Storage V3700 V2 and V3700 V2 XP storage systems provide the following key features and benefits: Scalable, modular storage with dual-active intelligent array node canisters with 8 GB (V3700 V2) or up to 16 GB (V3700 V2 XP) cache per canister.
  • Page 3: Components And Connectors

    More drives and expansion enclosures are designed to be dynamically added with virtually no downtime, which helps to quickly and seamlessly respond to ever-growing capacity demands. The Lenovo Storage V3700 V2 and V3700 V2 XP storage systems are designed to offer high levels of system and data availability with the following technologies:...
  • Page 4 Figure 4. Rear view of the Lenovo Storage V3700 V2 Control Enclosure The following figure shows the rear view of the Lenovo Storage V3700 V2 XP Control Enclosure. Figure 5. Rear view of the Lenovo Storage V3700 V2 XP Control Enclosure...
  • Page 5: System Specifications

    The following figure shows the rear of the Lenovo Storage V3700 V2 Expansion Enclosure. Figure 6. Rear view of the Lenovo Storage V3700 V2 Expansion Enclosure System specifications The following table lists the Lenovo Storage V3700 V2 and V3700 V2 XP storage system specifications. Table 1. System specifications Component...
  • Page 6 Up to 13,000 / 28,000 disk write IOPS Up to 27,000 / 55,000 disk mixed (70% read/30% write) IOPS Up to 3.4 / 6.2 GBps sequential disk read throughput Up to 0.96 / 1.7 GBps sequential disk write throughput Lenovo Storage V3700 V2 and V3700 V2 XP...
  • Page 7 * Performance measurements in a system unconstrained by the number of HDDs. ** For a detailed list of configuration limits and restrictions for a specific version of the Spectrum Virtualize for Lenovo Storage V3700 V2 Software V7, refer to the Lenovo Support website: http://support.lenovo.com...
  • Page 8: Control Enclosures

    При обращении используйте промокод AND-PDF и получите скидку. Control enclosures The following table lists the models of the Lenovo Storage V3700 V2 and V3700 V2 XP control enclosures. Table 2. Lenovo Storage V3700 V2 and V3700 V2 XP control enclosures...
  • Page 9 Each node canister has one expansion slot for an optional host interface card (HIC). The following host interfaces can be added to the Lenovo Storage V3700 V2 and V3700 V2 XP control enclosures with optional HICs (if HICs are used, two HICs of the same type are required per one control enclosure):...
  • Page 10 ** Maximum quantity shown is for models without / with integrated 12 Gb SAS host ports. The Lenovo Storage V3700 V2 and V3700 V2 XP control enclosures provide 12 Gb SAS internal dual-port drive connectivity, and each control enclosure also has two 12 Gb SAS x4 (Mini-SAS HD SFF-8644) ports (1 port per node canister) for 12 Gb SAS expansion enclosure connectivity.
  • Page 11: Expansion Enclosures

    При обращении используйте промокод AND-PDF и получите скидку. Expansion enclosures The Lenovo Storage V3700 V2 and V3700 V2 XP control enclosures supports attachment of up to nine Lenovo Storage V3700 V2 expansion enclosures. Intermix of LFF and SFF enclosures is supported. The enclosures can be added to the system non-disruptively.
  • Page 12 Feature expansion Description number code enclosure Lenovo Storage V3700 V2 0.6m 12Gb SAS Cable (mSAS HD) 01DC675 AU4P Lenovo Storage V3700 V2 1.5m 12Gb SAS Cable (mSAS HD) 01DC677 AU4R Lenovo Storage V3700 V2 3m 12Gb SAS Cable (mSAS HD)
  • Page 13 При обращении используйте промокод AND-PDF и получите скидку. Drives The Lenovo Storage V3700 V2 and V3700 V2 XP LFF control and expansion enclosures support up to 12 LFF hot-swap drives, and the SFF enclosures support up to 24 SFF hot-swap drives.
  • Page 14 To help evaluate the benefits of these new capabilities, licensed functions (with the exception of FlashCopy upgrade) can be enabled at no charge for a 90-day trial period. Trials are started from the Lenovo Storage management GUI and do not require any Lenovo intervention. Upon expiration of the trial, the function is automatically disabled unless a license key for that function was installed onto the machine.
  • Page 15 The remote mirroring option must be acquired (or licensed) for the primary (local) and secondary (remote) systems. If the Lenovo Storage V3700 V2 or V3700 V2 XP is mirrored to another system, the other system must have the appropriate and applicable license for remote mirroring.
  • Page 16: Power Supplies And Cables

    При обращении используйте промокод AND-PDF и получите скидку. Power supplies and cables The Lenovo Storage V3700 V2 and V3700 V2 XP enclosures have two redundant hot-swap 800 W AC power supplies, each with an IEC 320-C14 connector. The Lenovo Storage V3700 V2 and V3700 V2 XP enclosures ship standard without power cables. Rack power cords or country-specific line cords should be ordered with the enclosures (see the following table;...
  • Page 17: Warranty

    6.2 bels (operating) Warranty The Lenovo Storage V3700 V2 and V3700 V2 XP have a three-year Customer Replaceable Unit (CRU) and onsite warranty with 9x5/next business day (NBD) terms. Lenovo offers the service upgrades through warranty maintenance upgrades and post-warranty maintenance agreements with a well-defined scope of services, including service hours, response time, term of service, and service agreement terms and conditions.
  • Page 18 адрес: 125480, г.Москва, ул.Туристская, д.33/1; site: https://andpro.ru тел: +7 (495) 545-4870 email: info@andpro.ru При обращении используйте промокод AND-PDF и получите скидку. The warranty service definitions for the Lenovo Storage V3700 V2 and V3700 V2 XP systems are listed in the following table.
  • Page 19: Regulatory Compliance

    Lenovo provides end-to-end storage compatibility testing to deliver interoperability throughout the network. The Lenovo Storage V3700 V2 and V3700 V2 XP support attachment to Lenovo System x®, ThinkServer®, and Flex System™ hosts by using SAS, iSCSI, FC, or FC over Ethernet (FCoE) storage connectivity protocols.
  • Page 20 Lenovo Storage V3700 V2 and V3700 V2 XP iSCSI storage. Currently available converged FCoE/iSCSI adapters for Lenovo servers that are compatible with the Lenovo Storage V3700 V2 and V3700 V2 XP are listed in the following table. Other HBAs also might be supported (see the Interoperability Matrix for details).
  • Page 21 Currently available FC adapters for Lenovo servers that are compatible with the Lenovo Storage V3700 V2 and V3700 V2 XP FC storage are listed in the following table. Other HBAs also might be supported (see the Interoperability Matrix for details).
  • Page 22 The following table lists currently available Ethernet and FC rack-mount switches that are currently offered by Lenovo that can be used with the Lenovo Storage V3700 V2 and V3700 V2 XP in storage solutions. Table 18. Ethernet and FC rack-mount switches...
  • Page 23: Rack Cabinets

    Blade Storage Modules: http://lenovopress.com/servers/blades/storagemodule?rt=product-guide Operating systems The Lenovo Storage V3700 V2 and V3700 V2 XP support host attachments to the System x servers, ThinkServer systems, and Flex System compute nodes running the following operating systems: Microsoft: Microsoft Windows Server 2012 R2...
  • Page 24: Power Distribution Units

    При обращении используйте промокод AND-PDF и получите скидку. Rack cabinets The following table lists the rack cabinets that are currently offered by Lenovo that can be used with the Lenovo Storage V3700 V2 and V3700 V2 XP in storage solutions.
  • Page 25: Uninterruptible Power Supply Units

    DPI Australian/NZ 3112 Line Cord (32A) 40K9617 DPI Korean 8305 Line Cord (30A) 40K9618 For more information, see the list of Product Guides in the Power Distribution Units category: http://lenovopress.com/servers/options/pdu Uninterruptible power supply units Lenovo Storage V3700 V2 and V3700 V2 XP...
  • Page 26: Lenovo Financial Services

    Uninterruptible power supply units The following table list the uninterruptible power supply (UPS) units that are currently offered by Lenovo that can be used with the Lenovo Storage V3700 V2 and V3700 V2 XP in storage solutions. Table 22. Uninterruptible power supply units...
  • Page 27: Related Publications And Links

    For more information, see the following resources: Lenovo Storage product page: http://www.lenovo.com/systems/storage Lenovo Hardware Configurator: http://lesc.lenovo.com Lenovo Storage V3700 V2 and V3700 V2 XP Documentation http://support.lenovo.com/us/en/products/Servers/Lenovo-Storage/v3700v2? tabName=Documentation Lenovo Storage V3700 V2 and V3700 V2 XP Support: http://support.lenovo.com/us/en/products/Servers/Lenovo-Storage/v3700v2 Related product families...
  • Page 28 Web sites. The materials at those Web sites are not part of the materials for this Lenovo product, and use of those Web sites is at your own risk. Any performance data contained herein was determined in a controlled environment.
  • Page 29 При обращении используйте промокод AND-PDF и получите скидку. Trademarks Lenovo, the Lenovo logo, and For Those Who Do are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at http://www.lenovo.com/legal/copytrade.html.

This manual is also suitable for:

V3700 v2 xp

Table of Contents