Rack Installation; Physical Specifications; Operating Environment - Lenovo System x3650 M5 Product Manual

Hide thumbs Also See for System x3650 M5:
Table of Contents

Advertisement

Rack installation

The following table lists the rack installation options that are available for the System x3650 M5 server.
Table 33. Rack installation options
Description
4-post rail kits (distance between the front and rear mounting flanges; mounting hole types)
System x Enterprise Slides Kit (617 mm - 812 mm; round/square)
System x Gen-II Universal Slides Kit (617 mm - 812 mm; threaded/round/square)
System x M5 Custom Rail Kit (595 mm - 746 mm; round/square; no CMA support)
Cable management arm (CMA)
System x Enterprise 2U Cable Management Arm (CMA)
Lockable front bezel
System x3650 M5 Lockable Bezel
Front VGA port
System x3650 M5 EIA L - VGA
* The System x CMA requires the Enterprise Slides Kit (00FK656) or Universal Slides Kit (00KA500). The Custom Rail Kit (00MW239) is not
supported with the CMA.
Note: The System x Enterprise Slides Kit, part number 00FK656, is included with the standard models that are listed
in Table 2 and TopSeller models that are listed in Table 3.

Physical specifications

The System x3650 M5 server has the following dimensions and weight (approximate):
Height: 87 mm (3.4 in.)
Width: 434 mm (17.1 in.)
Depth: 755 mm (29.7 in.)
Weight:
Minimum configuration: 19 kg (41.8 lb)
Maximum configuration: 34 kg (74.8 lb)

Operating environment

The System x3650 M5 server is supported in the following environment:
Air temperature:
Server on: 5 °C to 40 °C (41 °F to 104 °F); altitude: 0 to 950 m (3,117 ft); decrease the maximum
system temperature by 1 °C for every 175-m increase in altitude above 950 m.
Server off: 5 °C to 45 °C (41 °F to 113 °F)
Maximum altitude: 3,050 m (10,000 ft), 5 °C to 28 °C (41 °F to 82 °F)
Shipment: -40 °C to +60 °C (-40 °F to 140 °F) at up to 10,700 m (35,105 ft)
Humidity:
Server on: 8% to 85%, maximum dew point 24 °C, maximum rate of change 5 °C/hr
Server off: 8% to 85%, maximum dew point 27 °C
Design to ASHRAE Class A3, ambient of 36 °C to 40 °C (96.8 °F to 104 °F), with relaxed support:
Supports cloud-like workload with no performance degradation acceptable (Turbo-Off).
Under no circumstance can any combination of worst-case workload and configuration result in
system shutdown or design exposure at 40 °C.
The worst-case workload (like Linpack, Turbo-On) might have performance degradation.
Lenovo System x3650 M5 (E5-2600 v4)
Part
Feature
Maximum
number
code
supported
00FK656
A5FV
1
00KA500
A5FW
1
00MW239
ATLQ
1
00FK622
A5FX
1*
00FK660
A5G0
1
00YD071
ATE9
1
40

Advertisement

Table of Contents
loading

Table of Contents