Vent-Axia VA140/150KP Installation And Wiring Instructions

Vent-Axia VA140/150KP Installation And Wiring Instructions

Range axial kitchen fans

Advertisement

Quick Links

VA140/150
RANGE
Axial Kitchen Fans
Installation and wiring Instructions
220-240V~50Hz
READ IN CONJUNCTION WITH ILLUSTRATIONS
PLEASE SAVE THESE INSTRUCTIONS
Stock Ref.No
VA140/150KP
VA140/150KT
VA140/150KHP
VA140/150KHT
140120C
140220C
140320C
140420C

Advertisement

loading

Summary of Contents for Vent-Axia VA140/150KP

  • Page 1 VA140/150 RANGE Axial Kitchen Fans Installation and wiring Instructions Stock Ref.No VA140/150KP 140120C VA140/150KT 140220C VA140/150KHP 140320C VA140/150KHT 140420C 220-240V~50Hz READ IN CONJUNCTION WITH ILLUSTRATIONS PLEASE SAVE THESE INSTRUCTIONS...
  • Page 2: Safety And Guidance Notes

    C. Ensure that the mains supply (Voltage, Frequency, and Phase) complies with the rating label. D. The Fan should only be used in conjunction with the appropriate Vent-Axia products. E. It is recommended that the connection to the fan connector terminals is made with flexible cable.
  • Page 3: Wall Mounting

    INSTALLATION. PANEL MOUNTING 1. Cut a 152mm hole through the panel. (Suitable for existing holes up to 185mm). 2. Remove the Indoor Grille [A]. Loosen the screw (top middle) of the Grille, to release front grille gently lever the Grille downwards away from the Inner Cover [B]. 3.
  • Page 4 Fig. 2. On the outside, one SPACER will always be required. Dependant on the thickness of glass either the thick or thin spacer will be used. For thin (single glaze) glass the additional spacer should be fitted on the inside behind the fan, engaging the locating pips.
  • Page 5 Fig. 4. VA140/ 150KT Timer Model. Timer Adjuster. Timer Adjustment. The overrun time period is factory set to approximately 15 minutes. The overrun time period may be adjusted at installation from 5-30 minutes, by altering the adjuster on the Fan PCB. Before adjusting the timer, switch off the Mains Supply.
  • Page 6 Fig. 5. 1 Phase Supply VA140/ 150KHP Humidity Model. (220-240V 50Hz). FUSE Switched Fused Spur Humidity Adjuster. Humidity Set-Point Adjustment. The Fan’s Humidity Set-Point is factory set to switch the fan on at approximately 72%RH. The sensitivity may be adjusted at installation from 65%RH-90%RH, by altering the adjuster on the Fan PCB. Before adjusting the Set-Point, switch off the Mains Supply.
  • Page 7: Servicing And Maintenance

    Humidity and Time Set-Point Adjustment. The fan’s Humidity Set-Point is factory set to switch the fan on at approximately 72%RH. The sensitivity may be adjusted from 65%RH - 90%RH, by altering the adjuster on the Fan PCB. The overrun Time period is factory set to approximately 15 minutes. The overrun time period may be adjusted from 5-30 minutes, by altering the adjuster on the Fan PCB.
  • Page 8 Vent-Axia guarantees its products for two years from date of purchase against faulty material or workmanship. In the event of any part being found to be defective, the product will be repaired, or at the Company’s option replaced, without charge, provided that the product:- ...