6 PTZ control
Camera remote control interface
Interface RS-232
Interface RS-485
48
As physical camera interfaces may differ from camera system to camera
system,
SmartDisc
02 is equipped with an RS-232 as well as an RS-485
interface. This avoids additional costs and reduces installation and wiring
requirements.
The following diagram shows the system described above:
Camera
remote control
Relay contacts
interface with
device specific
camera protocol
#1
#2
Illustration: Camera remote control with SmartDisc 02
Camera system data lines (e.g. Dome) are connected with terminals TxD, RxD
and GND (see "24 pin terminal block" on page 18). Please note that only one
camera can be connected when using interface RS-232, for technical reasons.
Camera system data lines (e.g. Dome) are connected with terminals D-, and
D+ (see "24 pin terminal block" on page 18). Up to two remote-controllable
cameras can be operated at the RS-485 interface with the same data protocol
with SmartDisc
02.
Refer to the enclosed installation CD for more device specific
documentation on how to connect and start the camera system.
Video
LAN / WAN
Remote control
Remote control
relays
Remote control
dome cameras
SmartControl
SmartControl PRO
Vista SmartDisc 02