4. Adjustments
[Modification of an Inspection Lens to an Adjustment Lens]
[It is common with FinePix S1 Pro]
* If an inspection interchangeable lens is used as is, the
aperture will change automatically, so there will be no
convergence [ISO sensitivity adjustment] and it could result
in an error.
Therefore,
(1) The CPU signal contact unit inside the lens must be
removed.
(2) The protrusion for mounting on the camera must be
removed from the inspection interchangeable lens to
prevent it from switching its aperture automatically, and
thus modify the lens so it can be used for adjustment.
The modification procedure is shown below.
[Step 1]
Turn the focus ring (1) so that the interchangeable lens's
distance scale reads 0.45, then place the lens upside down.
FORCUS RING
[Step 2]
Cut the stopper for the camera using side cutters, etc.
42
DISTANCE SCALE
1
Side cutter
2
FinePix S3Pro Service Manual
[Step 3]
Remove the screws holding the opening F value linkage
guide in the order shown by the circled numbers in the figure
below, then remove the opening F value linkage guide (5).
4
4
[Step 4]
Cut off the FPC of the CPU signal contacts with scissors, etc.
FPC
NIPPER
[Step 5]
Fasten the opening F value linkage guide with the mounting
screws.
Aperture indexing post
5
4
3
3
CPU CONTACTS
FPC
6