2. Disassembly
FinePix S3Pro Service Manual
2-9.
Removing the CCD PWB ASSY and CCD UNIT
(1) Remove the SHIELD SHEET.
1
(2) Remove the 3 screws (CCD PWB SCREW).
2
(3) Remove the EMI SHEET L in the direction of the arrow.
(4) Remove the EMI SHEET R in the direction of the arrow.
3
4
17