Maintenance - Projecta SC030 Manual

12 volt 30 amp automatic solar charge controller
Table of Contents

Advertisement

Status
Bulk Charge
LED (BLUE)
Bulk Charge
ON
Solar Power
Flashes
Weak
Float Charge
OFF
Mode
BATTERY CHARGE LEVEL INDICATOR L.E.Ds
The bottom 3 LED indicator lights show the batteries level of charge.
The green LED indicates the battery voltage is greater than 12.5V.
The yellow LED indicates the battery voltage is between 11.5V and 12.5V.
The red LED indicates the battery voltage is less than 11.5V.
The red LED will blink if battery is disconnected from the unit. The charge controller will
not function if not connected to both the battery as well as the solar array. Testing may not
be performed while the charge connector is unhooked from one or both of the batteries or
solar array.
When Solar Power is weak as well as during the night the charger will turn off the
charging LED.

MAINTENANCE

The following maintenance is recommended to be performed every three months:
1. Ensure all wire connections are sound and free from corrosion. Tighten terminal block screws
for both the solar array as well as the battery terminals.
2. Visually check the solar array and battery wiring for signs of overheating, damage, and
cracking. Replace any wires showing wear with new wires of the same gauge.
3. Verify each LED status to ensure match with specifications using a voltmeter.
6
Charge Complete
Conditions
LED (GREEN)
OFF
Indicates the battery is charging.
Power is being allowed to pass through
to the battery.
OFF
Indicates the solar panel voltage
is too low when in Bulk Charge mode or
insufficient sunlight.
ON
Indicates fully charged battery and a small
charge will continue to pass to the battery
in order to maintain a full charge state.