4
5
Hook the panel to the fixing devices starting from the
top aligning brackets
6
At this point, alignment between the panel and ad-
jacent cabinets can be adjusted using the alignment
brackets and small brackets
7
Vertical alignment: tighten or loosen the screw in the
brackets to raise or lower the panel
9
Depth alignment: working from the inside of the door,
after lifting up the magnetic seal, adjust the panel posi-
tion so it is closer to or further away from the door using
the holes
and then fix the panel in position using the
10
holes
.
11
58
www.fhiaba.com · info@fhiaba.com · Tel +39 (0)434 420160 · Fax +39 (0)434 420161
.
6
and
.
7
8
8
.
9
Once the front panel has been adjusted, check that the gasket
has been repositioned correctly to assure the door/drawer
are closing correctly and avoid operational errors of the unit.

Installation

Built-in installation single appliance
For a built-in installation, to close gaps between the ap-
pliance and the adjacent cabinets, special side profiles
and aluminum covering frames are provided.
Operate as follows:
Push the appliance into the installation niche
1
If the unit is to be installed inside a niche or within an
enclosed structure, it is necessary to design a ventilation
shaft at the back of the niche to assure proper ventilation
at the back of the unit. A 5 mm gap is sufficient to prevent
overheating. Always mount front panels on door and dra-
wer before pushing the unit into its final position inside the
niche or structure.
Secure the appliance to the adjacent cabinets by fixing
to these the side profiles previously mounted on the ap-
pliance
.
2
To make this operation easier keep the door and the dra-
wer open.