1-6. Indicator Display

In this unit, the error status is indicated by the blinking of the indicator. There are ON/STANDBY indica-
tor and LAMP/COVER indicator on the upper case. The error differs depending on which indicator
blinks.
For details of the blinking state of indicator and the error, refer to the list below.
ON/STANDBY indicator (Blinks in red)
Error
Temperature error
ON
OFF
Fan error
ON
OFF
Power error
ON
OFF
System error-1
ON
OFF
System error-2
ON
OFF
System error-3
ON
OFF
System error-4
ON
OFF
Assembly error
ON
OFF
LAMP/COVER indicator (Blinks in red)
Error
Cover error
ON
OFF
Lamp error
ON
OFF
1-30 (E)
Number of
Status
blinking
2
The temperature inside of the unit exceeds
the tolerable range.
4
Any of fan does not operate normally.
6
The power is not output normally.
10
The data cannot be normally acquired from
the storage device (EEPROM) when the
power of sub-CPU is turned on.
11
The data cannot be normally acquired from
the storage device (EEPROM) when the
power of main-CPU is turned on.
12
The main-CPU does not operate normally.
13
The main-CPU does not operate normally.
14
The connector of temperature sensor is
disconnected.
Number of
Status
blinking
2
The lamp cover is removed.
3
The lamp does not light normally.
VPL-EX100