  • Page 1 DATA PROJECTOR VPL-EX100 VPL-EX120 VPL-EX145 VPL-EX175 VPL-F400H VPL-F400X VPL-F500X VPL-F700HL VPL-F700XL VPL-FH30 VPL-FH500L VPL-FX30 VPL-FX35 VPL-FX500L PROTOCOL MANUAL 1st Edition (Revised 3)
  • Page 2 ! 警告 このマニュアルは,サービス専用です。 お客様が,このマニュアルに記載された設置や保守,点検,修理などを行うと感電や火災, 人身事故につながることがあります。 危険をさけるため,サービストレーニングを受けた技術者のみご使用ください。 ! WARNING This manual is intended for qualifi ed service personnel only. To reduce the risk of electric shock, fi re or injury, do not perform any servicing other than that contained in the operating instructions unless you are qualifi ed to do so. Refer all servicing to qualifi...
  • Page 3: Table Of Contents

    Table of Contents 1. Overview 1-1. Introduction ................ 1 1-2. Glossary of Terms .............. 1 1-3. Protocol Stack Structure ............. 1 2. Common Commands 2-1. Sub Commands ..............3 2-1-1. ITEM List ..............3 2-1-2. Infrared Remote Command Code ......13 2-2.
  • Page 5: Introduction

    1. Overview 1-1. Introduction The projector is remotely controllable over RS-232C as well as Ethernet. It is useful for setting up the projector away from the operator. This protocol manual describes the specifi cations such as packet format and procedures for controlling the projector.
  • Page 6 SDCP specifi c command is described in the section 4-3-2. SDAP and SDCP (PJ Talk) are SONY original protocol stack, which are described in the sections 4-3-1 and 4-3-4 respectively. VPL Series PROTOCOL MANUAL...
  • Page 7: Common Commands

    2. Common Commands 2-1. Sub Commands Sub Command is the value which is used by Simplifi ed Command. Value is assigned for executing func- tion. For example, if you want to change the picture mode, the appropriate value assigned for the desired picture mode should be chosen.
  • Page 8 ITEM List For Screen <Table 1> <Table 2> Remarks Item Number Data Item Upper byte Lower byte Data Byte ASPECT FULL 0000h Set/Get NORMAL 0001h ZOOM 0003h FULL1 0007h FULL2 0008h 0009h 16:9 000Ah OVER SCAN 0000h 0001h ITEM List For Setup <Table 1>...
  • Page 9 ITEM List For Infrared Remote Command <Table 1> <Table 2> Remarks Item Number Data Item Upper byte Lower byte Data Upper byte Lower byte Infrared Remote Command Refer to Section Set only (15 bit category) 2-1-2. Infrared Remote Command (20 bit E category) Infrared Remote Command (20 bit EE category) *1: For using this item number, the simulation of the infrared remote controller is enable.
  • Page 10 ITEM List For Status <Table 1> <Table 2> Remarks Item Number Data Item Upper byte Lower byte Data Byte STATUS ERROR1 NO ERROR Get only LAMP ERROR FAN ERROR COVER ERROR TEMP ERROR D5V ERROR POWER ERROR WARNING TEMP NVM DATA ERROR STATUS POWER STANDBY START UP...
  • Page 11 VPL-FH500L/FX500L/F700HL/F700XL ITEM List For Picture <Table 1> <Table 2> Remarks Item Number Data Item Upper byte Lower byte Data Byte PICTURE MODE DYNAMIC 0000h Set/Get STANDARD 0001h PRESENTATION 0002h CONTRAST VALUE 0000h-0064h(0-100) BRIGHTNESS VALUE 0000h-0064h(0-100) COLOR VALUE 0000h-0064h(0-100) VALUE 0000h-0064h(0-100) SHARPNESS VALUE 0000h-0064h(0-100)
  • Page 12 ITEM List For Setup <Table 1> <Table 2> Remarks Item Number Data Item Upper byte Lower byte Data Byte INPUT TERMINAL 1 VIDEO 0000h Set/Get SVIDEO 0001h INPUTA 0002h INPUTB 0003h INPUTC 0004h INPUTD 0005h INPUTE 0006h MULTI SCREEN MODE 0000h TWIN 0001h...
  • Page 13 ITEM List For Status <Table 1> <Table 2> Remarks Item Number Data Item Upper byte Lower byte Data Byte STATUS ERROR1 NO ERROR Get only LAMP ERROR FAN ERROR COVER ERROR TEMP ERROR D5V ERROR POWER ERROR WARNING TEMP NVM DATA ERROR STATUS POWER STANDBY START UP...
  • Page 14 VPL-EX100/EX120/EX145/EX175 ITEM List For Picture <Table 1> <Table 2> Remarks Item Number Data Item Upper byte Lower byte Data Byte PICTURE MODE DYNAMIC 0000h Set/Get STANDARD 0001h PRESENTATION 0002h GAME 0003h LIVING 0004h CINEMA 0005h CONTRAST VALUE 0000h-0064h(0-100) BRIGHTNESS VALUE...
  • Page 15 0001h COMPONENT 0002h VIDEOGBR 0003h LAMP MODE HIGH 0000h STANDARD 0001h 0002h *: This item is disabled for VPL-EX100. ITEM List For Infrared Remote Command <Table 1> <Table 2> Remarks Item Number Data Item Upper byte Lower byte Data Upper byte...
  • Page 16 ITEM List For Status <Table 1> <Table 2> Remarks Item Number Data Item Upper byte Lower byte Data Byte STATUS ERROR1 NO ERROR Get only LAMP ERROR FAN ERROR COVER ERROR TEMP ERROR D5V ERROR POWER ERROR WARNING TEMP NVM DATA ERROR STATUS POWER STANDBY START UP...
  • Page 17: Infrared Remote Command Code

    VPL Series PROTOCOL MANUAL...
  • Page 18 VPL Series PROTOCOL MANUAL...
  • Page 19 VPL Series PROTOCOL MANUAL...
  • Page 20: Reply

    2-2. Reply <Table 3> Item Number Data Item Data Upper byte Lower byte Complete Undefi ned Command Size Error Select Error Range Over Not Applicable Check Sum Error Framing Error Parity Error Over Run Error Other Comm Error Error description Check Sum Error A check sum error occurred.
  • Page 21: Rs-232C

    3. RS-232C 3-1. Connection Communication is enabled by the use of a D-Sub 9 Pin cross (reverse) cable. The pin assignment of D-Sub 9 Pin and D-Sub 25 Pin is as follows. D-Sub 9 Pin D-Sub 25 Pin Name Shell = FG Grounding for safety protection or cable shield Transmission data Reception data...
  • Page 22: Communication Procedure

    3-3. Communication Procedure 3-3-1. Outline of Communication All communication between CONTROLLER (PC, etc.) and DEVICE (PROJECTOR) is performed by the command block format. Communication is started by the issue of a command at CONTROLLER and ended when the return data is sent to CONTROLLER after DEVICE receives the command. CONTROLLER is prohibited from sending several commands at one time.
  • Page 23: Command Block Format

    3-6. Command Block Format The block format of Simplifi ed Command for RS-232C as shown in the fi gure below. In this section, the block format for Simplifi ed Command is provided. 3-6-1. Simplifi ed Command [Send] The block format for sending request is shown below. [A9h] START CODE Put the item number.
  • Page 24: Packet Examples

    3-7. Packet Examples 3-7-1. Change “ASPECT” to “ZOOM” START CODE = A9h ITEM NUMBER = 0020h (ASPECT) SET/GET = 00h (SET) DATA = 0003h (ZOOM) CHECK SUM = 23h END CODE = 9Ah You will receive the packet below if the process is successfully completed. START CODE = A9h ACK/NAK = 0000h (Complete) ACK = 03h...
  • Page 25: Ethernet

    4. Ethernet Ethernet corresponding model VPL-FH30, VPL-FH500L, VPL-FX30, VPL-FX35, VPL-FX500L, VPL-F400H, VPL-F400X, VPL- F500X, VPL-F700HL, VPL-F700XL, VPL-EX145, VPL-EX175 4-1. Service 4-1-1. Advertisement The advertisement service is provided to facilitate development of a PC application that can automatically detect a projector on the network. This function is achieved by broadcasting the equipment information periodically to the network.
  • Page 26: Pj Talk

    4-1-2. PJ Talk By using PJ Talk, it is possible to communicate with PROJECTOR over Ethernet network. Both of set and get method are provided. This protocol is set to OFF by default. [Protocol] Item Description Protocol name SDCP (Simple Display Control Protocol) Transport Port number 53484 (Factory-shipments value)
  • Page 27: Communication Procedure

    4-2. Communication Procedure Communication sequence is shown below. SDCP commands must be issued by CONTROLLER and PROJECTOR responses to it. On the other hand, SDAP commands are sent by PROJECTOR and have no response from CONTROLLER. CONTROLLER PROJECTOR SDCP SET/GET Request The command is executed if it’s valid.
  • Page 28: Protocols

    4-3. Protocols 4-3-1. SDAP This section describes the SDAP packet structure. The number in the brackets shows byte. POWER HEADER PRODUCT NAME LOCATION COMMUNITY SERIAL NO. STATUS (12) (24) Fig.4-2 Packet structure 1. Header The header consists of ID (2 bytes), version (1 byte) and category (1 byte). 4441h (2) VERSION (1) CATEGORY (1)
  • Page 29: Sdcp

    COMMUNITY fi eld should consist of four alphanumeric characters (case sensitive). All display equipment has the default value “SONY” when shipped at the factory. COMMUNITY fi eld should be fi lled with four characters. Three characters or less are not allowed.
  • Page 30 4. COMMAND Field There are 2 types of COMMAND fi eld, which are REQUEST and RESPONSE. REQUEST command is sent to the PROJECTOR from CONTROLLER. On the other hand, RESPONSE command is sent by PROJECTOR as a response to the REQUEST command. (1) REQUEST Command COMMAND fi...
  • Page 31 (2) RESPONSE Command COMMAND fi eld for RESPONSE has 3 sub fi eld shown as follows. RESPONSE(1) ITEM NO(2) DATA LENGTH(1) Fig. 4-8 COMMAND Filed for RESPONSE 1) RESPONSE sub fi eld The response returns the result of the request. OK (01h) Indicates that the request was executed correctly.
  • Page 32 5. DATA Field The content to be fi lled in this fi eld depends on the COMMAND fi eld. For SET Request commands, appropriate DATA value accompanied with ITEM NO should be chosen. ITEM NO (item number) and its data is shown in the section 2-1-1. For the GET REQUEST and OK RESPONSE, this fi...
  • Page 33 0x8001 Model name Alphanumeric 12 characters If the number of characters is less than 12, the remaining digits are fi lled with 00h. 0x8002 Serial number 4 bytes The serial number is in the range of 00000000 to 99999999. 0x8003 Installation location Alphanumeric 24 characters If the number of characters is less than 24, the remaining digits are fi...
  • Page 34: Error Code

    7. ERROR CODE ERROR CODE has 2 bytes long. The table below shows the error code. Each error category is explained as follows. Category Error Error Code Item Error (01**h) Invalid Item Invalid Item Request Invalid Length Invalid Data Short Data Not Applicable Item Community Error (02**h) Different Community...
  • Page 35 An item that is not valid at present is specifi ed. Example: The item to switch the display is specifi ed when the main power is off. (2) Community Error This error occurs when community is different. Example: “ABCD” is specifi ed when “SONY” is set. VPL Series PROTOCOL MANUAL...
  • Page 36 (3) Request Error This error occurs when header or command is illegal. The conditions of occurrence of the respective errors are shown below. Invalid Version The version of the header is other than 2. Invalid Category The category does not match. Example: 0Bh is specifi...
  • Page 37: Snmp

    8. Packet Examples For setting the picture mode to dynamic, the packet should be as follows. HEADER (VERSION, CATEGORY) = (02h, 0Ah) COMMUNITY = “SONY” = (534F4E59h) COMMAND (REQUEST, ITEM NO, DATA LENGTH) = (00h, 0002h, 02h) DATA = 0000h The same result can be obtained by using ENCAPSULATION mode as well.
  • Page 38: Pjlink

    4-3-4. PJLink The following model is equipped with the PJLink class1 protocol. For details about this protocol, refer to the PJLink specifi cations published from JBMIA. You can turn on or off the PJLink protocol and set a password from the Web setting screen > Setup > Advanced Menu >...
  • Page 39 Command Data Remark ERST ? The following values are returned: 6th digit : Fan error 5th digit : Lamp error 4th digit : Temperature error 3rd digit : Cover open error 2nd digit : Filter error 1st digit : Other error The following values are assigned to each digit : 0 : No error, or detection impossible 1 : Warning...
  • Page 40 . Commands The following 14 commands are supported : (01) [Power control command] POWR (02) [Power status inquiry] POWR ? (03) [Input switch command] INPT (04) [Input switch inquiry] INPT ? (05) [AV muting command] AVMT (06) [AV muting status inquiry] AVMT ? (07) [Error status inquiry] ERST ? (08) [Lamp count/lamp time inquiry] LAMP ? (09) [Input switch list inquiry] INST ?
  • Page 41 (2) [Power status inquiry] POWR? This command obtains the projector’s power status. The projector responds as follows: Returns the following values when the power status is obtained: Standby or power-saving state : Returns “0”. Power ON state : Returns “1”. Cooling state, or cooling state during power-saving state : Returns “2”.
  • Page 42 (4) [Input switch inquiry] INPT? This command obtains the projector’s input status. The projector responds examples as follows: Returns the following values when the input status is obtained (The input channel varies depending on the model.): When the projector input is Video : Returns “21”.
  • Page 43 (7) [Error status inquiry] ERST? This command obtains the projector’s error status. The projector responds as follows: Returns the response for the error status in the following format. The error status is expressed with a six-digit number. 6th digit : Fan error 5th digit : Lamp error...
  • Page 44 (11) [Manufacturer name inquiry] INF1? This command obtains the manufacturer name. The projector responds as follows: When normal : Returns a manufacturer name (SONY). Projector error occurring (including warning) : Returns “ERR4”. (12) [Model name inquiry] INF2? This command obtains the model name.
  • Page 45: Dddp

    (13) [Other information inquiry] INFO? This command obtains other information. The projector responds as follows: When normal : Returns a space. Projector error occurring (including warning) : Returns “ERR4”. (14) [Class information inquiry] CLSS? This command obtains the class information. The projector responds as follows: When normal : Returns “1”.
  • Page 47 (操作,保守等) と異なる目的で本マニュアルを使用する ことを禁止します。 The material contained in this manual consists of information that is the property of Sony Corporation. Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose other than the operation or maintenance of the equipment described in this manual without the express written permission of Sony Corporation.
  • Page 48 VPL-EX100 (CN) VPL-EX100 (SY) VPL-EX120 (CN) VPL-EX120 (SY) VPL-EX145 (CN) VPL-EX145 (SY) VPL-EX175 (CN) VPL-EX175 (SY) VPL-F400H (CN) VPL-F400X (CN) VPL-F500X (CN) VPL-F700HL (CN) VPL-F700XL (CN) VPL-FH30 (SY) VPL-FH500L (SY) VPL-FX30 (SY) VPL-FX35 (SY) Printed in Japan Sony Corporation VPL-FX500L (SY) E 2010.