18.0-A301 (Top cover)

*Befor installing 0-A301, confirm installed condition for parts.
*There is no bent for Main SW contact and confirm that the contact is the same hight.
(1) Apply G151 to land of Main SW contact.
(2) Confirm that the land for Main SW on T200 is not shorted by solder.
(3) Put top cover to body.
(4) Solder 3 lead wires. (Pink, Purple, Black)
(1)
G151
(5) Pop-up Flash for installing screw.
(6) Arrange 3 lead wires between body and top cover, then attach
top cover to the body without pinching lead wires.
(7) Connect T51 Flex + Fold Excess Flex under Top cover
(8) A73 (TY screw x2, 4.5mm)
(9) A73 (TY screw)
(10) A74 (TY screw x2, 5.5mm)
(11)TY-CNL-D1.7x8.0 (Battery chamber)
(8)
(3)
(7)
76700 -50/94-
(4) Pink
Purple
Black
(A330)
(2) Main SW
Land
(5)
(10)
(9)