Adjustment Items - Pentax K100D Service Manual

Hide thumbs Also See for K100D:
Table of Contents

Advertisement

(8) If the adjustment result was NG, the following screen display
■ SR unit adjustment, List of error code
Items
Coil direction check
Hole gain adjustment
Movement range adjustment
Gyro offset adjustment

Adjustment items

Contents of error
Error code: First 2 number is for cheking item number
And last number is for Error classification
Error
code
11 – 0
USB communication error
11 – 1
Coil reverse
12 – 0
USB communication error
12 – 1
Gain over limit [T100]
12 – 2
Gain_X over limit [C0 block]
12 – 3
Gain_YL over limit [C0 block]
12 – 4
Gain_YR over limit [C0 block]:
13 – 0
USB communication error
13 – 1
Range is too narrow
13 – 2
Center is over limit
14 – 0
Communication Error
14 – 1
Offset value is over limit
14 – 2
Gyro is unstable
76700 -45/94-