7.0-S300
① Arrange the lead wires from motor as shown
Figure and then attach 0-S300
② TY-CNL-D1.7x3.5
③ TY-CNL-D1.7x5.5
④ Install S364 as shown in a figure.
⑤ Apply screw lock
⑥ A115
⑦ TY-CNL-G1.7x2.5
8. 【ADJ】 AF Joint stroke
[Required equipment] Vernier calipers
① Set the AF lever to the AF position
② AF coupler(0-S300) must be projected from the mount surface by 1.2mm or more.
③ When the mount lock pin comes to the mount surface with depressing the mount lock lever,
the AF coupler must not be projected out of the mount surface.
④ Adjustment- 0-A121 by turning an eccentric screw, and apply the screw lock
SL
76700 -25/94-
0-S300
SL
S364

Hide quick links: