  • Page 2: Table Of Contents

    Table of Error Code (Digital adjustment)............. AE Program line and APEX chart (ISO 200)............Feature of K100D INFORMATION OF JIGS, TOOLS AND TESTERS FOR K100D....... Jigs, Tools and Testers................Method for making hand made jig................. Chart for SR gain adjustment.................
  • Page 3: Preparation

    1. Prepare SD card (7 pcs) for confirming adjustment Prepare SD card (7pcs). (1) For product FW (Firmware) of K100D (2 pcs) : use for service and updating FW for customer. (2) For switch test. (3) For test mode ON (4) For test mode OFF.
  • Page 4 (5) Copy the file of [kb393.bin] from [GM_FW] holder (For service) to SD cards. [CAUTION] You should use latest firmware whenever creating the SD cards for updating. * You should distinguish SD card by name label etc. (6) Copy the file of [fwdc156b.bin] from [DL_FW] holder (For update) to SD cards (7) Excute [Set up the VB run time] on next section 3.
  • Page 5 ③ Click OK ④ Do not click Directory, Click installation button 76700 -4/94-...
  • Page 6 ⑤ Set up will be started ⑥ Click OK to end the installation 76700 -5/94-...
  • Page 7: Disassemby And Assenbly

    DISASSEMBLY AND ASSEMBLY Outline of Disassembly and Assembly 1. Caution (1) Be sure to use the anti-static mat and wrist strap to prevent static failure of circuits. (2) This product is used lead free solder. surface of solder will be white-tinged color. Solder quickly, because melting temperature is high and so if heat to much, it is possible to damage to PC board.
  • Page 8 (3) FRONT HOUSING BLOCK..................(4) 0-Q200 (FLASH PC BOARD, A15 AND A15)............(5) A6 (LEFT SHOULDER PLATE)................(6) T901 (LOWER FLEX BOARD).................. (7) 0-A3 (BOTTOM PLATE ASSY).................. (8) T200 (UPPER FLEX BLOCK)................... (9) LCD BLOCK....................... (10) [CONFIRM] CCD BASE PLATE SUPPORT PILLAR..........(11) 0-C000..............
  • Page 9 20-11. SD CARD COVER SWITCH CHECK..............(21) [ADJUST] ADJUSTMENT WITH PROGRAMMED SOFTWARE (SLR OPERATION) 21-1 SETTING THE COMPUTER 21-2.PREPARATION 21-3 REGARDING THE ADJUSTMENT SCREEN 21-4 ADJUSTMENT/CHECK ITEMS 21-5 ADJUSTMENT PROCEDURE 21-6 END PROCEDURE (22) SR ADJUSTMENT II (GAIN ADJUSTMENT) 22-1 SETTING THE COMPUTER 22-2 SETTING FOR SR TESTER, PC 22-3 PREPARATION 22-4 ADJUSTMENT ITEMS...
  • Page 10: Disassembly And Assembly Procedures

    DISASSEMBLY AND ASSEMBLY PROCEDURES Disassembly procedure of main body [Preparation] Remove the Hot shoe cover FK, Eye cap FL and Battery from the main body. 1. POP-up the built-in flash For removing top cover, install the batteries to the camera and turn on the camera then pop-up the flash by pressing pop-up button.
  • Page 11 3. A161 (Side cover) ② ① Unscrew A74 (TY screw 5.5mm) ① ② Unscrew A73 (TY screw 4.5mm) ③ Unscrew A67 (screw 5mm) ③ ④ Remove a screw (CNL-D 1.7x2.5) 【Caution】Be careful the electric shock where flash circuit board is inside the cover. ⑤...
  • Page 12 ④ Unscrew A73 (TY screw x2 4.5mm) --- It is already done at 1-② ⑤ Unscrew A73 (TY screw) ⑥ Unscrew A74 (TY screw x2 5.5mm) ⑦ Unscrew TY-CNL-D 1.7x8.0 (Inside of battery chamber) ⑤ ④ ⑦ ⑥ ⑧ Lift up top cover. ⑨...
  • Page 13 6. 0-A201 (Back cover) ① Open the SD card cover. ② Unscrew A74 (TY screw x2 5.5mm) ② ① ③ Remove the terminal and lift up the back cover. ④ Disconnect 2 flex board from connector. ③ ④ ⑥ ⑤ ⑤...
  • Page 14 7. 0-T100 (Main PC board) ① Peel off BT(6x15) --- 3 points ② Peel off A38(PT3.8x10) while holding flex board. Unsolder lead wires. ③ Unsolder 2 lead wires. (Red, Black /Q200) ④ Unsolder 2 lead wires. (Black, Red /T200, A14) ⑤...
  • Page 15 ⑬ Remove 0-T100 while disconnecting T200 connector as shown in figure bellow. ⑭ Disconnect the flex from CCD/SR on 0-T100 ⑬ ⑭ 0-T100 8. CCD/SR Block 【Caution】Pay attention, there is powerful magnet is carried in the inside of a CCD/SR block. 【Caution】Since performance can be damaged, a CCD/SR block cannot be disassembled and also don't apply the external pressure to a movable part.
  • Page 16 ③ * Lift up LCD block as shown figure below. ④ ③ Disconnect T200 flex from connector. (Flip lock type) ④ Disconnect O100 flex from connector. (Flip lock type) ⑤ Remove A335. ⑥ ⑥ Remove BO2.0. ⑤ ⑦ ⑦ Remove A17 (spring) 10.
  • Page 17 ⑩ ⑨ ⑨ Unscrew CNL-D 1.7x1.8 (x5) ⑩ Unscrew TY-CNL-D 1.4x2.5 (x2) ⑪ Peel off main SW flex and Av-SW flex from double stick tape. (T200 separates.) ⑨ ⑪ ① ② 11. 0-A3 (Bottom plate assy.) ① Unscrew CNL-D 1.7x2.5 (x4) ②...
  • Page 18 ② ① 12. T901 (Lower flex board) ① Unsolder 13 lands. (M100) ② Unsolder 7 lands. (T301) ③ Remove T901. ④ Unscrew TY-CNL-D1.7x3.5 ⑤ Remove A141. ④ ⑤ ③ ⑥ ④ ⑤ 13. A6 (Left shoulder plate) ③ ① Unscrew TY-CNL-D 1.7x3.5 ②...
  • Page 19 15. Front housing block ① Supply DC2V to 0-S250 (Mirror motor). (Positive (+) on Red wire) Set the front housing block to mirror up position. ② Unscrew TY-CNM 2.0x5.0 (x5) ③ Remove main plate and battery chamber from front housing block. ①...
  • Page 20: Assembly And Disassembly Procedure Of Front Housing Block

    II. Assembly and Disassembly procedure of front housing block *Disassemble the front housing block in revese order of assembly procedures 【 】 Assembly procedures 1. Front Housing Block A102, B41, M120, (DT(4x15)), B58 x2, B59, TY-CNL-G 1.7x2.0, 0-B52 (mirror sheet), B66 (shaft) ----A screw lock (SL) and L115 are applied.
  • Page 21 ⑧ ⑦ ⑦ Install B17 to B9. ⑧ Inatall B18 to B9. ⑨ 0-B8 ----Apply G126 to surface of cam. ⑨ ⑩ B7 ⑪ ----Apply G126 to surface of cam on both side. ⑪ Align the both hole of 0-B8 and B7. ⑩...
  • Page 22 ⑲ 0-G100 ----Surely install G100 without any gap between plate. Pink (45mm) ⑲ ⑳ TY-CNL-D1.7x3.0(x4) Purple (40) ⑳ DT(5x15) Red (80mm) Black (80) 【Arrangement when replace G100】 1. Arrange the lead wires with DT(5x15) as shown in figure 2. Solder 4 lead wires. 3.
  • Page 23: [Confirm] Checking The Mirror Function

    3. M1 *B65, M4, and M18 should be attached with M1 ① M1 ② TY-CNL-D1.7x4.5(x2) ① ② 4. 【CONFIRMATION】 Checking the mirror function [Required equipment] Power supply ① Confirm the following points while applying DC2V to the mirror motor. (Red wire: Positive) -1) The mirror seat must be moved smoothly without noise.
  • Page 24: A104

    5. A104 ① ① 0-A121 ② A133 ② ③ TY-CNL-F1.4x4.0 ③ ⑤ ④ ④ 0-A126 ----and related parts. G134 Apply G134 as shown figure ⑤ TY-CNL-D1.7x3.0 G134 ⑥ A105 ---- Apply G134 as shown figure ⑦ A110 ⑥ ⑧ 0-A108 ⑧...
  • Page 25: [Adjust] Positioning 1St And 2Nd Mirror

    6. 【ADJ】Positioning 1 and 2 Mirror [Required equipment] 1 mirror angle (45°) adjusting jig, Mirror angle adjusting jig for 27830, Mirror positioning scope. *Adjustment is performed by turning B58 (2 pcs). The Y-axis (the vertical direction) is adjusted to a 0 target. *Front housing must set mirror down position.
  • Page 26: 7)0-S300

    7.0-S300 ① S364 ① Arrange the lead wires from motor as shown Figure and then attach 0-S300 0-S300 ② TY-CNL-D1.7x3.5 ② ③ TY-CNL-D1.7x5.5 ④ Install S364 as shown in a figure. ③ ④ ⑥ ⑤ ⑦ ⑤ Apply screw lock ⑥...
  • Page 27: L2. 0-L101

    9. L2, 0-L101 【Caution】 Confirm there is neither dust nor scratch on L2 and 0-L101. ① M3 ② 0-L101---- Apply Super X (black) to three places ② Super-X(Black) ① ③ M9(M8・M12 x2) ④ ③ ④ TY-CNL-D1.7x3.0(x 2) ⑤ TY-CNL-D1.7x4.5 ⑤ 【Note of Disassembly】...
  • Page 28: M301

    ② ① 10. M301 ① Eyepiece (M301,L7 and other) ② TY-CNL-D1.7x4.0(x2) 11.SI block ① Confirm that there is neither dust nor scratch on inside prism and mirror. ② SI block(0-M51, 0-M52, M53, L11, L12, 0-O170 and other) ③ Attach M55 (SI spring) as shown figure ④...
  • Page 29: [Adjust] Positioning 0-O170 (Si-Led)

    ② 【Adjust】Exchanges for M22 of other thickness. The tolerance level at the time of adjustment is 0±0.04 M22-00A -00B -00C -00D -00E -00F -00G -00H -00I -00J t=0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.55 0.60 13. 【ADJ】Positinoning 0-O170(SI-LED) 【Required equipment】Power supply, lead wires ①...
  • Page 30: 0-O100

    14. 0-O100 ① Apply small quantity of diabond (black) to the shown in figure ② M2 prism --- There should be no dust ③ 0-O100 ④ Fix it with TY-CNL-F1.7x3.0(x 2) * Install screws while pressing the plate of 0-O100 ③...
  • Page 31: 0-M100

    M125 16.0-M100 Preparation: Hexagonal screwdriver 1.5mm ① 0-M100 (when replacing 0-M100 put M125 at sensor side) ② TY-CNL-D1.7x4.0(x3) [ADJ] Temporary adjustment of AF block --- Screw in 3 ① adjusting screws until they stops, then screw back two turns. [NOTE] After CCD position adjustment with programmed software is done, Apply screw-lock agent to between the head of adjustment screws and washers.
  • Page 32: Assembly Procedure Of Main Body

    3. Assembly procedure of main body 1. Main body + Battery chamber (1) A13 Battery chamber and relating parts. [Caution]Check the position of lead wires and battery seal. TY-CNS2.0x4.5 TY-CNL-D1.7x3.5 Gray Black Super-X (Black, x3) N300 White Yellow Black TY-CNL-D TY-CNL-B 1.7x3.5(x3) 1.4x3.0...
  • Page 33: Front Housing Block

    3. Front housing (1) Apply DC 2V to the mirror motor, and set mirror up position. (Red --- +) (2) To prevent the damage of SI-LED, attach mount cover. Then put downward. (3) Attach body plate to the mirror housing. * Pay attention the lead wires and flex.
  • Page 34: A6 (Left Shoulder Plate)

    5. A6(Left shoulder plate) (1) A6 --- Arrange the lead wires and flex as shown figure. (2) CNL-D1.7x2.5 (3) TY-CSM1.7x4.0 (x3) (4) TY-CNL-D1.7x4.0 (5) A19 (6) TY- CNL-D1.7x3.0 (7) TY-CNL-D1.7x3.5 (In battery chamber) 6. T901(Lower flex board) (1) A141 (2) TY-CNL-D1.7x3.5 (3) T901 (4) Solder 7 lands (T301) (5) Solder 13 lands (M100)
  • Page 35: 0-A3 (Bottom Plate Assy)

    7. 0-A3(Bottom plate assy) (1) When installing 0-A3, arrange the flex and lead wires as shown figure. (2) CNL-D1.7x2.5 (x2) (3) TY-CNL-D1.7x4.0 (x2) (4) CNL-E1.7x2.2 (Ni, x2) (5) TY-CSM1.7x4.0 (6) Attach A53 on plate (7) CNL-D1.7x1.8 (8) Attach two lead wires by DT as shown figure.
  • Page 36: Lcd Block

    (4) Arrange lead wire (A14) as shown figure. (Through the grove of battery chamber) (5) Install flex by TY-CNL-E1.7x3.5 (6) Fix flex by A40 (tape) *Flex shoud move up and down a little. (7)Arrange lead wires. (Flash PC boad side) (8) Solder 6 lead wires (T940, S300) (9) Solder 7 lamds (O170) (10)
  • Page 37: [Confirm] Ccd Base Plate Support Pillar

    *Install LCD block (6) TY-CNL-D1.7x3.5 (x2) (7) CNL-D1.7x2.5 LCD block (8) [Confirm] You must feel click when turning electronic dial. 10. [CONF] CCD Base Plate Support Pillar [Required equipment] Block gauge for 35mm, Dial gauge comparator, etc. (same as MZ series) (1) Measure height of the CCD base support pillar (3 places) from the mount surface as shown in the figure.
  • Page 38 11. 0-C000 (CCD/SR block) *To prevent the damage of SI-LED, attach mount cover. Then put downward. [Caution] CCD/SR block has strong magnet inside threrfore, caution for adsorption of parts. [Caution] There is no dust, no scratch on surface of CCD (1) [Confirm] Center plate must move up and down and right and left by own weight.
  • Page 39: 0-T100 (Main Pc Board)

    12. 0-T100 (Main PC board) *When replacing T100, transfer the related parts as shown figure. [Caution] Be cairful when handling 0-T970. Inside of 0-T970 might be broke by impact or drop. [Caution] Solder 4 lead wires at T100 side and arrange read wairs. Solder (DT18x18) (5)T979...
  • Page 40 (3) TY-CNL-D1.7x3.5 (x2) (4) CNL-D1.7x2.5 (x2) (5) Connect T901flex (Flip lock) (6) Connect J100flex (Flip lock) Solder lead wirs (7) 1 lead wire (Gray, I17) (8) 4 lead wires (Black/Rred/Yellow/White, T10/N300) (9) 4 lead wires (Gray/Orenge/Black/Red, S300/ S250) (10) 2 lead wires (Black/Red, GND/BATT+) (11) 2 lead wires (Red/Black, Q200) (12) Fix J100 flex by A38 (PT3.8x10) (13) Arrange all read wires as shown figure then fix three positions by BT (6x15)
  • Page 41: [Confirm] Function Check 1

    13. [Confirm] Function check 1 [Required equipment] SD card for adjustment 4pcs (FW for service, Data initialize, Test mode ON, Test mode OFF) Regulated DC power supply (8V/3A), Circuit tester, DC code, AC adaptor, TV color monitor, Video cable, Top cover (0-A301), Bottom cover (A401), Lens for confirmation (FA 50mm F1.4), 13-1.
  • Page 42: Writing Firmware

    UPDATE VER.1.00.00.10 [NOTE] If you want to cancel writing firmware, >>> EJECT SD CARD <<< disconnect AC adapter and eject the SD card. PENTAX K100D UPDATING DSP FIRMWARE (4) Remove the SD card when the message as SECTOR** >> PROGRAM >>>...
  • Page 43: Shutter Release And Exposure

    13-6. Shutter release, exposure (1) Shutter release function works properly. (2) Diaphragm setting lever move up and down when set the Main SW change to Preview mode (Default setting: Digital Preview) (3) The information of Tv must be changed when the e- dial is turned. (4) Set TV [1/8], and then check if shutter open fully.
  • Page 44: Sr Adjustment I (Unit Adjustment)

    14. [Adjustment] SR adjustment- 1 [Caution 1] When replacing T100 or C000 block, you must excute this adjustment. [Caution 2] Excute the adjustment on the stable table and do not give vibration to the camera while adjusting [Required equipment] Programmed software for 76700 (for SR unit adjustment), SR adjustment stand Computer (Windows 2000 or Xp, USB port as standard equipment), USB cable, AC adaptor, Lens (FA 50mm), SD card for confirmation (For test mode OFF) 14-1.
  • Page 45: Adjustment Procedure

    14-4. Procedure for adjustment (1) Connect the camera to the computer via USB cable. (2) Start up the computer and connect the AC adapter (Power ON). (3) Confirm that the camera is recognized by computer. (hot plug icon). (4) Click [76700 SR Operation Adjustment] in the adjustment software folder (5) Adjustment screen will be displayed.
  • Page 46: Adjustment Items

    (8) If the adjustment result was NG, the following screen display Adjustment items Contents of error Error code: First 2 number is for cheking item number And last number is for Error classification ■ SR unit adjustment, List of error code Error Items Contens...
  • Page 47: End Procedure

    14-5.Procedure for Ending the program soft Finish the program soft with following procedure (1) When the following screen displayed, turn the power of the camera OFF and click OK button on the screen (2) Click Exit button and finish the program soft. (3) Disconnect AC adaptor, USB cable.
  • Page 48: A150 (Front Cover)

    15. A150 (Front cover) (1) Install A150 while noticing direction of 4 lead wires. (2) CNL-D1.7x2.5 (3) Solder 4 lead wires (Black, Red, Blue and White) (4) Arrange lead wires as shown figure. Black Blue White 16. A201 (Back cover) *Befor installing A201, confirm installed condition for parts.
  • Page 49 (6) A74 (TYscrew x2, 5.5mm) (7) Close SD card cover 76700 -48/94-...
  • Page 50: [Adjust] Positioning 0-J100

    17. [Adjustment] Positioning 0-J100 [Required equipment] Penlight or equivalent *Confirm that the mirror seat is downed condition. Pen-light (1)Cover the eyepiece with a hand or black tape. Sensor (2)Positioning the penlight to the photo sensor as shown in the figure right, and search the position where the Mirror pattern of the photo sensor can be seen on the 1 mirror...
  • Page 51: 0-A301 (Top Cover)

    18.0-A301 (Top cover) *Befor installing 0-A301, confirm installed condition for parts. *There is no bent for Main SW contact and confirm that the contact is the same hight. (1) Apply G151 to land of Main SW contact. (2) Confirm that the land for Main SW on T200 is not shorted by solder. (3) Put top cover to body.
  • Page 52: A161 (Side Cover)

    (11) Connect T51flex. (flip lock) part of bent into top cover. (12) Fix the flex by A39 (BT 6x10). (13)Solder 4 lead wires (Blue, Green, Black, Brown- Q100) (14)Arrange lead wires as shown figure. (13) Black (11) Blue (12) Green A39 (BT6x10) Brown (15) After install, check the function of AE-L button and Av button.
  • Page 53: Confirm] Function Check

    20. [Confirm] Function check 2 [Required equipment] CF card 2pcs (for SW testing and Taking picture), Battery adaptor, Regulated DC power supply (8V/3A), DC cord, Circuit tester, Lens for checking (FA50mmF1.4), Cable switch CS-205, remote control F, Flash for checking (AF360FGZ etc) 20-1.
  • Page 54: Switch Test (Each Sw And Conntact Of Dial)

    20-5. [Confirm] Switch and dial Function (1) Turn the main SW to OFF and insert the SD card for Testing into the camera. (2)Turn the main SW to ON while opening the SD card cover, and the screen for SW testing will be displayed on the LCD monitor. (3) Operate each SW and the dial according to the LCD monitor.
  • Page 55: Shooting And Playback Function

    20-6. Shooting, Playback check (1) Turn the main SW to OFF and insert the SD card (for Taking picture) into the camera. (2) Turn the main SW ON (3) Press the MENU button and format the SD card according to indication of LCD monitor.
  • Page 56: Adjust] Si-Led Position

    20-9. [Adjustment] vertical position of SI-LED * If position of SI-LED is moved vertical direction by condition of installing top cover, Adjust with next procedure. (1) Pop-up the flash and remove M5. (2) Turn internal sdjusting screw (3) Confirm the LED position and apply screw lock to foot of screw. ADJ.
  • Page 57 21-3.Adjustment screen When click the adjustment software, the following screen will be displayed Menu bar A. Tool bar Product number 76700 B. USB communication display C. Menu screen Adjust/Check items A.Tool bar USB open: start the communication with camera (Same as [USB Test] in the menu bar) USB close:Close the communication with camera (same as [USB Test] in the menu bar)...
  • Page 58 C.Menu screen When click the each items, the detail will be displayed as follow. 21-4.Items for adjustment/Check 1:[Eeprom checking] Check the data 2:[Exposure adjust] Adjustment the exposure [BV adjust] (brightness value) Adjustment of brightness value 3:[AF and related adjust] Adjustment of AF [CCD position adjust] AF sensor position [AGC level adjust] AGC level adjustment [Uniformity adjust] Adjustment that equalizes output of AF sensor...
  • Page 59 *Confirmation: [Connect] should display as follow 76700 Connect ⑦ Execute the check/adjustment following the display screen as follows PDC Adj T100ExChange Initialize the data Did you exchange the Writing of initial EPROM. main pc board? (Yes/No) Replaced Main PCB? 6:BATTERY LEVEL ADJUST 1:EEPROM CHECKING ↓...
  • Page 60 ↓ POSITION CHECK [AGC LEVEL ADJUST] [UNIFORMITY ADJUST] [FOCUS OFFSET ADJUST] TEMP ADJUSTMENT( Select . /F . Input temperature . Temp Adjust . Close) HORIZONTAL・VERTICAL* (START . Adjust position of chart . STOP . ADJUST . Close) 5:EEPROM CHECKING When finished all adjustment, click 5:EEPROM CHECKING * When replaced T100, the following adjustment should be done additionally 6:BATTERY LEVEL ADJUST...
  • Page 61 ③ Double-click hot plug icon of the taskbar at the lower right of a desktop, and then follow "safe removal of hardware." -> "PENTAX USB DISK Device" ④ Turn the power of the camera OFF and remove AC adaptor, USB cable (Battery cover and temporally bottom cover can stay for the next adjustment)...
  • Page 62 ◆ Gain adjustment P C Chart 22-3.Preparation 1) Set the zooming position at 200mm and distance ring set at 2m and then fix each setting with tape 2) Attach lens to the camera 3) Set the camera to the following condition Mode dial: M AF switch: MF SR switch: ON...
  • Page 63 22-5 Adjustment procedure ① Connect the camera to the computer via USB cable ② Turn the power of the computer and attach AC adaptor to the camera ③ Turn the power of the camera ON and confirm that computer is recognized theUSB connection ④...
  • Page 64 ⑨ When display OK, the adjustment is completed ⑩ Click [Quit] and finish the adjustment ⑪ Click [Removing the hardware] on the screen of PC ⑫ Turn the power of the camera OFF and disconnect the AC adaptor, USB cable from the camera ⑬...
  • Page 65 (1) Copy the folder『76700』from the CD-ROM into the Computer. *Log data will be created automatically whenever the camera is adjusted. 76700 23-2. Setting of K100D (1) Attach the master lens 76180 and Diaphragm set ring F8 to the camera. (2) Set mode dial to [M].
  • Page 66 23-4. Procedure of adjustment (1) Connect the AC adaptor to the camera. (2) Connect the camera to the computer by the USB cable (3) Attach the Master lens to camera while confirming the aperture of Master lens is set to F8. (4) Turn the main switch ON, and then confirm that the camera is recognized as a [Removable Disk] under [My Computer] (5) Set the camera and master lens toward center of light window of LB3300, and then cover the...
  • Page 67 (8) Select「CCD Input」 * When replaced T100 or CCD ----- Select “Manual-ID” * Other than above ----- Select “Auto” (9) When select [Manual-ID] Input CCD ID No 2 times Input ID No. ↓ Press “Execute” button or ・ Manual-ID “Enter” key ↓...
  • Page 68 (11) When the screen display as follows, the adjustment is completed. (12) Double-click hot plug icon of the taskbar at the lower right of a desktop, and then follow "safe removal of hardware. Turn off the camera and disconnect the camera. [Error massage] * The following display appear when the mode dial of the camera is not set on [M].
  • Page 69 23-5 WDC Adjustment procedure [NOTE] CCD white pixel defect compensation item only can be adjustable by this procedure. (1) Connect the AC adaptor to the camera. (2) Connect the camera to the computer by the USB cable (I-USB17). (3) Turn the main switch ON, and then confirm that the camera is recognized as a [Removable Disk] under [My Computer].
  • Page 70 24. Shutter speed adjustment by histogram (1/4000 sec) [Caution] * Adjustment (SLR function and Digital function) should be completed before * Shutter speed adjustment required when replaced T100 or 0-E000. * When check the shutter speed by the reflection type of the shutter tester, follow the SLR function adjustment in the service manual.
  • Page 71 [Caution] Position of histogram must be the following fig 2. If the position of histogram is Fig1,Fig3 or Fig4 (NG), check the setting the camera again. Also, re-adjust BV and digital adjustment. * Set same light value (LV8 or LV9) and Set aperture at F1.4 (Open position) 7) Set TV at 4000 and ISO 3200 (When set LV9: TV 4000 and ISO 1600) 8) Set the camera to the light box and capture 5 images 9) Playback the image by histogram display and compare the peak position with standard data.
  • Page 72 11) Obtain the shutter speed (mS) referring the conversion table (next page) * In the case of above, difference of peak position is + 1.5mm (Right side of the standard) and histogram zone is B Object camera: istDL / DL2 / DS2 (Size of monitor is 2.5inch) ---- Shutter speed is [0.273ms] Standard Tv4000 Conversion table of shutter speed Step 1: compare the peak position with standard data.
  • Page 73 24-4 Adjustment procedure 1) Start the adjustment software and connect the camera to the computer 2) Select SHUTTER SPEED ADJUSTMENT 3) Select the 1/4000 shutter tester and go to data input screen. 4) Input conversion data (mS). If the data is NG, back to the data input screen and input [0.25] and finish the adjustment 5) After finish the adjustment, execute the software adjustment and then disconnect the connection.
  • Page 74 26. 【CONF】Final function check 3 * Excute [Function check 2] if necessary. 26-1. Confirmation of the metering function * The checking method is the same as *istD series. 【Required equipment】 Light source (Shutter tester), FA50mm F1.4 ① Attach the lens (FA50mm) to the camera and set the aperture to the A position. ②...
  • Page 75 AE Master Lens (P) F・FA 50mm F1.4(∞) LV6~14 +0.25~-1.00 +0.70~-0.50 LV15 (Multi-segment) +0.75~-0.50 +1.20~±0.00 ■K100D, Correlation table of EV with Y: -1.0 -0.5 ±0 +0.5 +1.0 [Note] The standard is applied only when the camera is set to the condition as mentioned above.
  • Page 76 26-4.BC (Battery check) Preparation: Battery adaptor, Power supply, Cercuit tester DC5.6V → Lighting DC5.4V → Lighting 26-5. Confirmation of AF focus by taking a picture DC4.6V → Blinking Confirmation is the same as *istD (76180). This section describes the method of checking the AF focus for your reference. It will enable you to do the overall confirmation of the position of the AF focus, and also will be useful in the service.
  • Page 77 If camera is OK, There is possibility for trouble with the lens. 26-6.Confirmation of SR mechanism Preparation: Personal computer, AC adaptor, USB cable, FA50mm lens, SD card(For test), Application software (PENTAX PHTO Browser 、Adobe Photoshop) 、ACDSee ① Attach FA50mm lens to the camera and set aperture ring at A position.
  • Page 78 Confirmation of SR mechanism (When use different type of focal length) The shutter speed of prevention for shaking is calculate with [1 / focal length of the lens] For instance, if the focal length is 200mm: 1/ (200 x 1.5) = 1/300 * Size of picture for digital camera is 23.5 x 15.7mm and it is about 1.5 times when converting it into the focal length of 35milli-size camera.
  • Page 79 26-7. CCD Cleaning *This method of confirmation is assumption for CCD cleaning in service. [Required equipment] Computer, AC adaptor, USB cable, AF 50mm F1.4 (or F1.7), Light box, Cleaning paper for CCD (Clean wipe-P), solvent for cleaning (EE6310 or C600), Tweezers (recommend to use flat tip), SD card for test, Image viewing software (e.g.
  • Page 80: Fw Firmware

    [Supplement] Dust on the CCD Cause of dust into the camera. → Dust enters from outside of the camera when changing the lens. Dust stick by moving mirror or shutter. According to CCD characteristic the static electricity occurs when taking a picture and so the condition is dust stick easily.
  • Page 81: Updating Firmware Version (1)

    (7) Turn the main switch to OFF when the following message [POWER OFF] is appeared. (Updating is completed) (8) Insert the SD card into the camera again then PENTAX K100D UPDATING DSP FIRMWARE turn on the power condition with opening SD SECTOR** >>...
  • Page 82: Updating Firmware Version (2)

    3. Updating Firmware Version (2) [Required equipment] Latest product Firmware for customer update (SD card), AC adaptor, fully charged battery. [CAUTION] 1. If power is shut down during updating firmware, electric part in the camera will be damaged. 2. When executing this updating, the camera will not be set default setting. (1) Install the battery and connect the AC adaptor to the camera.
  • Page 83: Technical Information

    TECHNICAL INFORMATION Battery consumption current Condition : Lens [FA lens, A position], each mode and setting is default setting. ○ × Lens---- : With : Without ○ × SD card---- : With : Without *5,6 and 7 are peak value averages AC Power Battery Condition of camera...
  • Page 84: Block Diagram

    Block diagram 76700 -83/94-...
  • Page 85: Table Of Error Code (Digital Adjustment)

    Table of Error Code (Digital adjustment) * It is the same as istD series. The error code is displayed as “aa-xx-xx-yy—zz” (example : 03-07-01-07-00) to explain the detailed error. aa : Adjustment item when error is happened xx : Not use in service yy : Type of error zz : Contents of error (aa)
  • Page 86: Ae Program Line And Apex Chart (Iso 200)

    AE Program line (normal) and APEX chart (ISO200) * Standard program exposure mode (DA F 3.5-5.6 / 18-55mm) 76700 -85/94-...
  • Page 87: Feature Of K100D

    • Since the SR system is activated only when you press the shutter release, any effect on battery consumption is negligible. • PENTAX SR is optional. You can leave SR on permanently, turning it off only when using a tripod or panning (deliberately moving the camera in the direction of subject motion to blur the background).
  • Page 88 SR system because its operation is instantaneous, occurring within the normal exposure interval. • By building the Shake Reduction system into the body, the PENTAX SR system provides maximum flexibility and requires no compromises in optical quality.
  • Page 89 The K100D incorporates a large 2.5-inch color LCD monitor on its back panel. Its wide-view design allows the photographer to check the monitor image over 140 degrees vertically and horizontally, ensuring effortless image viewing even from a diagonal position.
  • Page 90 3. 11-point wide-frame AF to capture off-center subjects in crisp focus The K100D's sophisticated SAFOX VIII autofocus system features 11 sensor points (with nine cross-type sensors in the middle) to automatically focus on the subject with utmost precision, even when it is positioned off center.
  • Page 91: Information Of Jigs, Tools And Testers For K100D

    Information of Jigs, Tools and Testers for K100D Order No. * Exclusive use for *K100D(76700) No.95901-P408 Program soft for 76700 (For SRL/digital, supply with CD-ROM) Program soft for 76700 (SR function, supply with CD-ROM) No. 95901 Temporary bottom cover (Hand made) --- Refer to the Method for making temporally bottom cover...
  • Page 92 AC adaptor (D-AC10) USB cable (I-USB17) Video cable (I-VC28) Color video monitor (With a video input terminal) Clean wipe-P (For CCD cleaning paper) 60boxes: No.95901-A14 1 boxes : No.95901-A15 Light source for AE adjustment * Light value should equipped [LV6・8・10・12・16] or [LV6・9・12・15]. AE master lens for LX (LML-240, 95901-D20 can be used No.95901-N27 AF positioning jig (Square) for 27830...
  • Page 93: Method For Making Hand Made Jig

    Method for making the hand made jig 1. Method for making temporally bottom cover Preparation: A401 bottom cover ① Cut off part of bottom cover as shown in figure. φ7 2. Method for making temporally battery cover (For battery adaptor) Preparation: A412 battery cover ①...
  • Page 94: Chart For Sr Gain Adjustment

    Chart for SR Gain adjustment (1) When print this chart, print out the page with high quality setting. ■ (2) Size of the center of the chart should be 17 x 17mm 76700 -93/94-...
  • Page 95: Af Confirmation Chart And Scale

    ◎ ◎ ◎ ◎ ◎ ◎ C※◎◎E AF confirmation chart and scale ◎ ◎ ◎ ◎ ◎ ◎ B※◎◎E * This conformation is apply for service ◎ ◎ ◎ ◎ ◎ ◎ A※◎◎E ◎ ◎ ◎ ◎ ◎ ◎ 9※◎◎E ■...