Available languages

Cold water
Min. water pressure/flow pressure
(Liquid
Max. water pressure/flow pressure
dispensing)
Max. throughput
(Option)
1 inlet hose with ¾" threaded union included
(optional).
On-site connection thread
Length of inlet hose
Waste water
Max. waste water temperature
Drain valve
Waste water connection on machine (ext. diameter)
Drain connection on site (int. diameter)
Max. transient throughput
Vented drainage required. If ventilation is insufficient, fit Miele
kit, Mat. No. 05238090.
Drain manifolds serving several machines must be of
sufficient cross-section.
Fittings
Without base
The machine must be firmly anchored to the floor!
Anchor fittings included:
The floor must be solid and able to support the machine. The
fittings included are suitable for a solid concrete floor. Anchor
bolts and fittings for other floor types must be provided on
site.
On concrete base
The machine must be firmly anchored to the floor!
Anchor fittings included:
The grade of concrete should be suitable for the load. The
base should be firmly anchored to the floor to accommodate
dynamic stress!
Miele base
The base must be firmly anchored to the floor!
Anchor fittings included with plinth:
Both the machine and the base must be installed according to
the installation instructions provided.
Machine data
Machine width
Machine depth
Machine height
Casing width
Casing depth
Min width of delivery access to installation site
Recommended rear wall gap (measured to front of machine)
Minimum rear wall gap (measured to rear of machine lid)
Net weight
Dynamic floor load, max.
Static floor load, max.
Dynamic load, max.
Drum frequency, max.
Average heat dissipation
(dependent on ambient room temperature and program
selected)
Sound pressure level (re 20 mPA),
workplace-related (at distance of 1 m and height of 1.6 m)
Installation should only be carried out by authorized fitters in accordance with valid regulations!
Observe installation instructions when installing machine! All rights reserved!
Technical datasheet: PW 6207 EL (electric)
Date: 03.2015
2 × bolts DIN 571 (Ø × length)
2 × rawl plugs (Ø × length)
2 × bolts DIN 571 (Ø × length)
2 × rawl plugs (Ø × length)
4 × bolts DIN 571 (Ø × length)
4 × rawl plugs (Ø × length)
14.5 psi
100 kPa
145 psi
1000 kPa
1.4 gal/min
5.5 l/min
Inch
¾" garden hose
thread, male
59 1/16"
1500 mm
203°F
95°C
2 15/16"
75 mm [DN 70]
2 15/16"
75 mm [DN 70]
52.8 gal/min
200 l/min
½" x 3 9/16"
12 x 90 mm
5/8" x 3 1/8"
16 x 80 mm
½" x 3 9/16"
12 x 90 mm
5/8" x 3 1/8"
16 x 80 mm
5/16 x 3 1/8"
8 x 80 mm
½ x 2 3/8"
12 x 60 mm
36 3/8"
924 mm
44 ½"
1130 mm
55 1/8"
1400 mm
36 ¼"
920 mm
40 3/16"
1020 mm
36 5/8"
930 mm
57 1/16"
1450 mm
15 ¾"
400 mm
1120 lb
508 kg
6203 N
6203 N
5670 N
5670 N
533 N
533 N
18.3 Hz
18.3 Hz
5118 BTU/hr
1.5 kW
dB (A)
70 dB (A)