Your pump has been carefully packaged at the factory to
prevent damage during shipping. However, occasional damage
may occur due to rough handling. Carefully inspect your pump
for damages that could cause failures. Report any damage to
your carrier or your point of purchase.

INITIAL START UP PROCEDURES:

1.
Inspect the pump and the sewage tank for
any obvious condition that may
necessitates cleaning, correction,
adjustement or repair.
2.
Assure that the pump is secure and
vertical for proper operation.
3.
Assure that there is adequate clearance
from any combustible materials or
structure. Stored materials must be kept
away from the pump. Shelves or cabinet
structures must not be in close proximity
over the pump.
4.
Assure that the motor is securely plugged
into a proper 'GFCI' electrical outlet.
5.
Test the 'GFCI' outlet by pressing its test
switch. This should prove that the outlet is
energized and will trip off to protect against
a ground fault. Be sure to reset the 'GFCI'
by pressing its reset switch.
(Repeat this step monthly)
6.
Lift the float to assure that the pump will
start when required. (Step 7 below will test
submersible pumps with enclosed floats).
7.
Pour pails of water in the sewage tank to
turn the pump on. Assure that any check
valve present will permit the sewage to flow.
8.
Observe that the plumbing can pump the
sewage safely out of the residence.
(Repeat this step monthly)
© 2012 BUR-CAM Printed in Canada 450373TW
W W W. B U R C A M . C O M
Tel.: 514.337.4415
Fax: 514.337.4029
info@burcam.com
INSTALLATION
INSTRUCTIONS
MODEL
400505TW
SEWAGE
Please read these
carefully. Failure
to comply to
instructions and
may void the
PUMPS
instructions
designed
operation of
this system,
warranty.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 400505TW and is the answer not in the manual?

Questions and answers

Summary of Contents for Burcam 400505TW

  • Page 1 W W W. B U R C A M . C O M MODEL 2190 Dagenais Blvd. West Tel.: 514.337.4415 Laval (Quebec) Fax: 514.337.4029 400505TW Canada H7L 5X9 info@burcam.com SEWAGE PUMPS Your pump has been carefully packaged at the factory to prevent damage during shipping.
  • Page 2: Safety Instructions

    Safety instructions: This fine pump that you have just purchased is designed from the latest in material and workmanship. Before installation and operation, we recommend the following procedures: Check with your local electrical and plumbing codes to ensure you comply with the regulations.
  • Page 3 APPLICATIONS FEATURES Vortex designed impellers made from noryl, will not corrode. Designed for a permanent installation for homes Rugged cast iron pump body. and cottages application. To pumping where the total head requirements Stainless steel mechanical rotary type motor seals. do not exceed 15 feet, including pipe friction losses.
  • Page 4 When you are pumping raw sewage, you must have a gas tight cover on the basin and a vent STEP 5 pipe from basin, connecting to home’s vent system (see diagram). Feed the 2” riser pipe from pump’s discharge, through the 2” opening in the cover. Secure a 3” vent pipe to the vent opening and bring the switch and pump motor power cables through the opening in the cover provided.
  • Page 5: Repair Parts

    Secure cover. ÉTAPE 8 Verify the operation. ÉTAPE 2 Install sewage basin. ÉTAPE 4 Position of pumps. ÉTAPE 3 400505TW Air lock preven- tor hole drilling. (each pump) REPAIR PARTS # REF DESCRIPTION # REF DESCRIPTION 1 450525 Volute base...
  • Page 6 TROUBLE SHOOTING GUIDE CHECKLIST NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH THE POWER CONNECTED. DON’T JUST UNSCREW THE FUSE OR TRIP THE BREAKER, REMOVE THE POWER FROM THE RECEPTACLE. TROUBLE PROBABLE CAUSE ACTION Switch is off position Turn switch to on position Motor does Replace...

Table of Contents