Your pump has been carefully packaged at the
factory to prevent damage during shipping.
However, occasional damage may occur due to
rough handling. Carefully inspect your pump
for damages that could cause failures. Report any
damage to your carrier or your point of purchase.
NOTICE
This unit has been designed to
pump water only. This unit is
not designed for applications
involving salt water, brine or any
other liquids including petroleum
products. Use with salt, brine
or any other liquids including
petroleum products will void the
warranty.
ELECTRICAL CONNECTION
For pumping systems using more
than one pump, each pump
needs to be connected to its own
dedicated circuit protected by a
fuse or breaker. The use of dedicated
circuits will allow the other pumps
to continue functioning even if
the fuse or breaker of one of the
pumps trips .
Tel. : 514.337.4415
Fax : 514.337.4029
info@burcam.com
www.burcam.com
INSTALLATION
INSTRUCTIONS
300828BUP
SUBMERSIBLE
© 2024 BURCAM Printed in Canada 310343BUP
MODEL
version Z
SUMP PUMP
Please read these
instructions
carefully. Failure
to comply to
instructions and
designed
operation of
this system,
may void
the warranty.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 300828BUP and is the answer not in the manual?

Questions and answers

Summary of Contents for Burcam 300828BUP

  • Page 1 The use of dedicated circuits will allow the other pumps to continue functioning even if the fuse or breaker of one of the pumps trips . © 2024 BURCAM Printed in Canada 310343BUP...
  • Page 2: Safety Instructions

    SAFETY INSTRUCTIONS This fine pump that you have just purchased is designed from the latest in material and workmanship. Before installation and operation, we recommend the following procedures : Check with your local electrical and plumbing codes to ensure you comply with the regulations. These codes have been designed with your safety in mind.
  • Page 3 • Two (2) pumps have to be installed in the sump pit. The first pump as a primary pump and the second pump as the backup unit. • Burcam alarm system model 450455 has to be installed to advise you any malfunctions. • As sump pumps are electrically powered and activated so to prevent flooding, a Burcam battery powered back-up pump model 300403 has to be installed to evacuate the water.
  • Page 4: Maintenance

    SUMP PUMP APPLICATION (SEE DIAGRAM ON PAGE 6) At this step, you have the opportunity to install a 1 1/2” or a 1 1/4” discharge. STEP 3 We recommend a 1 1/2” ABS/DWV discharge. Connect your pipe to the provided piping of the pumps. The check valves are already installed at the pump discharges.
  • Page 5: Installation Steps

    INSTALLATION STEPS Installation of this unit may take several hours. Before disabling your main pump, have NOTICE ready appropriate means of evacuating the sump. 12 V BATTERY PUMP STEP 1 Turn off power to main pump. Check valve : If you install your emergency 12 V pump using the STEP 2 same discharge pipe of your main 115 V pump, a check valve is required between the T or Y connection and both pumps.
  • Page 6: Repair Parts

    310266 Oil Seal 310267 O Ring 310268 Screw 310269 Cable Cord And Nut 310270 Handle 450447 Vertical Switch 310271 Motor Assembly 310496 Float Bracket (not shown) Repair parts may be ordered your authorized point of sale of from BURCAM PUMPS...
  • Page 7 TROUBLE SHOOTING GUIDE CHECKLIST ELECTRIC PUMP NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH THE POWER CONNECTED. DON’T JUST UNSCREW THE FUSE OR TRIP THE BREAKER, REMOVE THE POWER FROM THE RECEPTACLE. TROUBLE PROBABLE CAUSE ACTION Switch is off position Turn switch to on position Motor does not run.
  • Page 8 TROUBLE SHOOTING GUIDE CHECKLIST NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH THE POWER CONNECTED. DON’T JUST UNSCREW THE FUSE OR TRIP THE BREAKER, REMOVE THE POWER FROM THE RECEPTACLE. TROUBLE PROBABLE CAUSE ACTION Connections not secure Check all connections Pump won’t Low or defective battery Check battery and replace if low...
  • Page 9: Instructions D'installation

    à des fusibles ou disjoncteurs indépendants. Ainsi, l’alimentation électrique d’une pompe ne sera pas interrompu si le fusible de l’autre pompe brûle ou si le disjoncteur de l’autre pompe se déclenche. © 2024 BURCAM Imprimé au Canada 310343BUP...
  • Page 10: Conseils De Sécurité

    CONSEILS DE SÉCURITÉ La pompe que vous venez d’acquérir est un produit fabriqué avec les meilleurs matériaux et par une main-d’oeuvre spécialisée. Veuillez suivre les instructions d’utilisation et prendre les précautions nécessaires pour votre sécurité : Consultez les normes de plomberie et d’électricité se rapportant à votre région, pour vous assurer des règles à...
  • Page 11: Étapes D'installation

    • Vous devez installer deux (2) pompes dans votre puisard. La première agira comme pompe primaire et la seconde servira d’unité de secours. • Le système d’alarme Burcam modèle 450455 doit aussi être pour vous signaler toutes défaillances. • Comme les pompes de puisard fonctionnent à l’électricité, pour prévenir une inondation, une pompe d’urgence à...
  • Page 12 APPLICATION DE POMPE PUISARD (VOIR LE DIAGRAMME À LA PAGE 6) Maintenant, vous avez la possibilité d’utiliser un tuyau de décharge de 1 1/2” ou ÉTAPE 3 de 1 1/4”. Nous recommandons une décharge de 1 1/2” ABS / DWV. Brancher votre tuyauterie à...
  • Page 13 INSTALLATION STEPS Pour protéger vos biens et assurer le temps nécessaire à l’installation, prévoyez une technique AVIS provisoire et fiable pour vidanger le puisard, lors du débranchement de votre pompe principale. POMPE À BATTERIE 12 V ÉTAPE 1 Débranchez complètement l’alimentation électrique de votre pompe principale. Clapet de retenue : si vous installez votre pompe d’urgence 12 V en utilisant le ÉTAPE 2 même tuyau de décharge que la pompe principale 115 V, un clapet de retenue...
  • Page 14: Pièces De Rechange

    Anneau en ‘‘O’’ 310268 310269 Câble d’alimentation et adaptateur du câble 310270 Poignée 450447 Interrupteur vertical 310271 Assemblage moteur 310496 Support de flotte (non illustré) Les pièces de rechange peuvent être commandées de votre point de vente autorisé ou de POMPES BURCAM...
  • Page 15: Guide De Résolution Des Problèmes

    GUIDE DE RÉSOLUTION DES PROBLÈMES POMPE ÉLECTRIQUE LORS D’AJUSTEMENT SUR DES APPAREILS ÉLECTRIQUES, TOUJOURS S’ASSURER QUE LE COURANT EST DÉBRANCHÉ. NE PAS SEULEMENT ENLEVER LE FUSIBLE OU METTRE LE DISJONCTEUR HORS TENSION. IL FAUT DÉBRANCHER LE CÂBLE D’ALIMENTATION DE LA PRISE. PROBLÈME CAUSE POSSIBLE ACTION Commutateur hors circuit...
  • Page 16 GUIDE DE RÉSOLUTION DES PROBLÈMES LORS D’AJUSTEMENT SUR DES APPAREILS ÉLECTRIQUES, TOUJOURS S’ASSURER QUE LE COURANT EST DÉBRANCHÉ. NE PAS SEULEMENT ENLEVER LE FUSIBLE OU METTRE LE DISJONCTEUR HORS TENSION. IL FAUT DÉBRANCHER LE CÂBLE D’ALIMENTATION DE LA PRISE. PROBLÈME CAUSE POSSIBLE ACTION Les branchements électriques ne Vérifiez tous les raccords et branchements...

Table of Contents