Download Print this page

Machine Connections - Miele PW 6207 Installations Plan

Hide thumbs Also See for PW 6207:

Advertisement

Available languages

Available languages

Machine connections:

Electrical
1. Standard voltage (as supplied)
connection
2. Standard voltage (convertible)
Electrical connection must comply with national regulations.
Connection using multi-pole lockable wall socket in
compliance with IEC/EN 60309 and IEC/EN 60947 is
recommended in order to simplify electrical tests. If machines
are hard-wired, a multi-pole mains switch must be provided
on site. Switches with a contact gap of more than 3 mm can
be used. These include switches, fuses and contactors
(IEC/EN 60947). A wall socket or mains isolator must be
easily accessible after installation.
Reinstallation of the supply point, changes to the equipment
or checks on the protective conductor, including determination
of correct fuse rating, should only be performed by a properly
trained electrician.
If necessary, equipotential bonding with good galvanic contact
must be provided in accordance with all appropriate national
and local regulations.
Equi-potential
Sleeve with external thread
bonding
for washer and nut
(Option)
Fitting such as washers and nuts are only supplied with the
OS machine version.
If necessary, equipotential bonding with good galvanic
contact must be provided in accordance with all appropriate
national and local regulations.
Steam
Indirect steam
connection
Steam pressure
Boiling point
Heater rating (on-site requirement)
Steam supply (on-site requirement)
Connection thread (on site)
Steam valve, steam filter and steam stopcock must be
provided on site.
Supply lead steam valve (length). The supply lead for the
electric steam valve is included.
The steam valve should be installed close to the steam
connection.
Follow installation instructions for steam-heated Miele
washer-extractors.
Condensate
Connection thread (on site)
connection
Stopcock and condensate separator to be provided on site.
The condensate drain should be installed in such a way that
the heater banks self-drain when the machine is not in
operation. Consequently, there should be no build-up of
condensate in the heater bank. The installation of bell-shaped
condensate drains is recommended.
Technical datasheet: PW 6207 D (steam)
Date: 03/2015
Frequency
Rated load
Fuse rating
Supplied without power cord
Frequency
Rated load
Fuse rating
Supplied without power cord
V
3 AC 208
Hz
60
kW
3
A
3 x 15
V
3 AC 220-240
Hz
60
kW
4.3
A
3 x 15
3/8 x 1 3/8"
10 × 35 mm
M 10
87 – 145 psi
600 - 1.000 kPa
305-363°F
152 –184°C
32kW
32kW
127lbs/h
58kg/h
½" internal thread
(NPT)
19 11/16"
500 mm
½" internal thread
(NPT)
Page: 12

Advertisement

loading