Resetting the display to factory
defaults - i60
During normal operation:
1. Press and hold the Display and True / App
buttons at the same time for approximately 14
seconds, until the Dealer Calibration page is
displayed.
2. Press the VMG and Tack buttons at the same
time to display the User Calibration Menu
Access page.
3. Press the Display button until the Factory Reset
page is displayed (5 presses from the User
Calibration Menu Access page).
4. To reset the display to factory default settings:
i. Use the VMG or Tack buttons to change the
reset option to F 1 (default).
ii. Press the Display button to reset your display
to factory default settings.
Note: To exit the dealer calibration pages at any
time press and hold the Display and True / App
buttons at the same time for approximately 2
seconds.