Gas Valve Coils
The burner assembly gas valve utilizes 2 coils. A
double coil (safety and booster coils combined) and
a single main coil are located on top of the gas valve
in front of the combustion chamber opening. The
coils can be replaced separately.
Gas valve coil assembly resistance values:
• Safety coil terminals - 1400 
• Booster coil terminals - 580 
• Main coil terminals - 1300 
To remove the double and main coils:
1. Remove the burner assembly from the dryer.
(See
2. Note the position of the locator pins inserted in
the coil bracket.
3. Remove the 2 Phillips-head screws that attach
the coil bracket to the valve body.
Main Coil
Booster Coil
Safety Coil
4. Lift the coil bracket vertically.
5. Lift coils vertically from valve assembly.
Note: Upon assembly, ensure the locator pins are
inserted into the holes provided in the coil bracket.
– 27 –
and follow steps 1 through 7.)
Gas Valve
Coil Bracket
Locator Pin
Locator Pin