Download Print this page

Makita BVF104 Technical Information page 5

Cordless garden sprayers
Hide thumbs Also See for BVF104:

Advertisement

R
epair
[3] DISASSEMBLY/ASSEMBLY
[3]-3. Fuse
Note: The following problems cause Fuse to be blown up. Therefore, solve the problems before replacing Fuse.
* Lock of Motor due to the intrusion of alien element
* Lock of Motor due to the rust by the liquid materials, leaking from Tank complete
DISASSEMBLING
(1) Remove Battery housing from Tank complete. (Fig. 14)
(2) Remove Fuse holder from Battery housing R by picking the near side Fuse holder with Slotted screwdriver, and then
pull off Fuse holder from Battery housing L.(Fig. 17)
(3) Turn Fuse holder in the direction designated by gray arrow. Fuse can be removed. (Fig. 18)
Fig. 17
Fuse holder
Fig. 18
Fuse holder
Note: Fuse of model BVF154 can be replaced without removing Battery housing from Tank complete.
Remove Pump holder from Tank complete as illustrated in Figs. 2 and 3, and then do the above step illustrated
in Figs. 17 and 18.
ASSEMBLING
Take the disassembling step in reverse.
Battery housing R
Near side of Fuse holder
Battery
housing R
Battery housing L
Fuse
P 5/ 7
Battery
housing L
Fuse holder

Advertisement